Affiliation:
1. Plateforme CYM – UMS‐IPSIT Université Paris‐Saclay, Inserm, CNRS, Ingénierie et Plateformes au Service de l'Innovation Thérapeutique Orsay France
2. Plateforme MIPSIT – UMS‐IPSIT Université Paris‐Saclay, Inserm, CNRS, Ingénierie et Plateformes au Service de l'Innovation Thérapeutique Orsay France
3. Inflammation, Microbiome and Immunosurveillance, UMR‐996 Université Paris‐Saclay, Inserm Orsay France
4. Service d'Hépato‐Gastroentérologie Et Nutrition, Hôpital Antoine‐Béclère AP‐ HP Université Paris‐Saclay Clamart France
Abstract
AbstractFlow cytometry is a relevant tool to meet the requirements of academic and industrial research projects aimed at estimating the features of a bacterial population (e.g., quantity, viability, activity). One of the remaining challenges is now the safe assessment of bacterial viability while minimizing the risks inherent to existing protocols. In our core facility at the Paris‐Saclay University, we have addressed this issue with two objectives: measuring bacterial viability in biological samples and preventing bacterial contamination and chemical exposure of the staff and cytometers used on the platform. Here, we report the development of a protocol achieving these two objectives, including a viability labeling step before bacteria fixation, which removes the risk of biological exposure, and the decrease of the use of reagents such as propidium iodide (PI), which are dangerous for health (CMR: carcinogenic, mutagenic, and reprotoxic). For this purpose, we looked for a non‐CMR viability dye that can irreversibly label dead bacteria before fixation procedures and maintain intense fluorescence after further staining. We decided to test on the bacteria, eFluor Fixable Viability dyes, which are usually used on eukaryotic cells. Since the bacteria had size and granularity characteristics very similar to those associated with flow cytometry background signals, a step of bacterial DNA labeling with SYTO or DRAQ5 was necessarily added to differentiate them from the background. Three marker combinations (viability‐DNA) were tested on LSR Fortessa and validated on pure bacterial populations (Gram+, Gram−) and polybacterial cultures. Any of the three methods can be used and adapted to the needs of each project and allow users to adapt the combination according to the configuration of their cytometer. Having been tested on six bacterial populations, validated on two cytometers, and repeated at least two times in each evaluated condition, we consider this method reliable in the context of these conditions. The reliability of the results obtained in flow cytometry was successfully validated by applying this protocol to confocal microscopy, permeabilization, and also to follow cultures over time. This flow cytometry protocol for measuring bacterial viability under safer conditions also opens the prospect of its use for further bacterial characterization.
Subject
Cell Biology,Histology,Pathology and Forensic Medicine
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献