Tuned exchange imaging: Can the filter exchange imaging pulse sequence be adapted for applications with thin slices and restricted diffusion?

Author:

Lasič Samo12ORCID,Chakwizira Arthur3ORCID,Lundell Henrik24,Westin Carl‐Fredrik5,Nilsson Markus6ORCID

Affiliation:

1. Department of Diagnostic Radiology Lund University Lund Sweden

2. Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research Copenhagen University Hospital ‐ Amager and Hvidovre Copenhagen Denmark

3. Department of Medical Radiation Physics, Lund Lund University Lund Sweden

4. MR Section, DTU Health Tech Technical University of Denmark Lyngby Denmark

5. Department of Radiology, Brigham and Women's Hospital Harvard Medical School Boston Massachusetts USA

6. Department of Clinical Sciences Lund, Radiology Lund University Lund Sweden

Abstract

AbstractFilter exchange imaging (FEXI) is a double diffusion‐encoding (DDE) sequence that is specifically sensitive to exchange between sites with different apparent diffusivities. FEXI uses a diffusion‐encoding filtering block followed by a detection block at varying mixing times to map the exchange rate. Long mixing times enhance the sensitivity to exchange, but they pose challenges for imaging applications that require a stimulated echo sequence with crusher gradients. Thin imaging slices require strong crushers, which can introduce significant diffusion weighting and bias exchange rate estimates. Here, we treat the crushers as an additional encoding block and consider FEXI as a triple diffusion‐encoding sequence. This allows the bias to be corrected in the case of multi‐Gaussian diffusion, but not easily in the presence of restricted diffusion. Our approach addresses challenges in the presence of restricted diffusion and relies on the ability to independently gauge sensitivities to exchange and restricted diffusion for arbitrary gradient waveforms. It follows two principles: (i) the effects of crushers are included in the forward model using signal cumulant expansion; and (ii) timing parameters of diffusion gradients in filter and detection blocks are adjusted to maintain the same level of restriction encoding regardless of the mixing time. This results in the tuned exchange imaging (TEXI) protocol. The accuracy of exchange mapping with TEXI was assessed through Monte Carlo simulations in spheres of identical sizes and gamma‐distributed sizes, and in parallel hexagonally packed cylinders. The simulations demonstrate that TEXI provides consistent exchange rates regardless of slice thickness and restriction size, even with strong crushers. However, the accuracy depends on b‐values, mixing times, and restriction geometry. The constraints and limitations of TEXI are discussed, including suggestions for protocol adaptations. Further studies are needed to optimize the precision of TEXI and assess the approach experimentally in realistic, heterogeneous substrates.

Funder

Vetenskapsrådet

Swedish Cancer Foundation

European Research Council

National Institutes of Health

Publisher

Wiley

同舟云学术