Abstract

AbstractA syringe‐based, semi‐automatic environmental monitoring device is developed for on‐site detection of harmful heavy metal ions in water. This portable device consists of a spring‐embedded syringe and a polydimethylsiloxane (PDMS) membrane‐based flow regulator for semi‐automatic fix‐and‐release fluidic valve actuation, and a paper‐based analytical device (PAD) with two kinds of gold nanoclusters (AuNCs) for sensitive Hg2+and Co2+ion detection, respectively. The thickness of the elastic PDMS membrane can be adjusted to stabilize and modulate the flow rates generated by the pushing force provided by the spring attached to the plunger. Also, different spring constants can drastically alter the response time. People of all ages can extract the fix‐volume sample solutions and then release them to automatically complete the detection process, ensuring high reliability and repeatability. The PAD comprises two layers of modified paper, and each layer is immobilized with bovine serum albumin‐capped gold nanoclusters (R‐AuNCs) and glutathione‐capped gold clusters (G‐AuNCs), respectively. The ligands functionalized on the surface of the AuNCs not only can fine‐tune the optical properties of the nanoclusters but also enable specific and simultaneous detection of Hg2+and Co2+ions via metallophilic Au+–Hg2+interaction and the Co2+–thiol complexation effect, respectively. The feasibility of the device for detecting heavy metal ions at low concentrations in various environmental water samples is demonstrated. The Hg2+and Co2+ions can be seen simultaneously within 20 min with detection limits as low as 1.76 nmand 0.27 µm, respectively, lower than those of the regulatory restrictions on water by the US Environmental Protection Agency and the European Union. we expect this sensitive, selective, portable, and easy‐to‐use device to be valid for on‐site multiple heavy metal ion pollution screenings in resource‐constrained settings.

Funder

National Taiwan University

National Science and Technology Council

Publisher

Wiley

Subject

Biomaterials,Biotechnology,General Materials Science,General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3