Technical note: Exploring the detectability of coronary calcification using ultra‐high‐resolution photon‐counting‐detector CT

Author:

Chang Shaojie1,Ren Liqiang1,Tang Shanshan1,Marsh Jeffrey F.1,Hsieh Scott1,McCollough Cynthia H.1,Leng Shuai1

Affiliation:

1. Department of Radiology Mayo Clinic Rochester Minnesota USA

Abstract

AbstractBackgroundCoronary calcification is a strong indicator of coronary artery disease, and patients with a “zero” coronary calcification score have a much lower risk of future cardiac events than those with even small amounts of calcium. However, false‐negative (incorrect zero scores) may occur if small calcifications are missed at CT due to limited spatial resolution.PurposeTo demonstrate lower limits of detection for coronary calcification using an ultra‐high‐resolution (UHR) mode on a clinical photon‐counting‐detector CT (PCD‐CT), compared to a conventional energy‐integrating‐detector CT (EID‐CT).MethodsChicken eggshell fragments (0.4–0.8 mm) mimicking coronary calcifications were scanned on a clinical PCD‐CT (NAEOTOM Alpha) in UHR mode and a conventional EID‐CT (SOMATOM Force) with matched tube potential and radiation dose levels to the PCD‐CT. PCD‐CT images were reconstructed with a sharp kernel (Qr68) and a quantum iterative algorithm (QIR‐3). Two sets of EID‐CT images were reconstructed: routine clinical kernel (Qr36, ADMIRE‐3) and a sharper kernel (Qr54) with similar noise to PCD‐CT images. With institutional review board approval, in vivo exams performed with the PCD‐CT in UHR mode were compared against patients’ clinical EID‐CT exams. The visibility of calcifications on PCD‐CT and EID‐CT images was assessed and compared qualitatively.ResultsPCD‐CT images visualized all calcified fragments, while EID‐CT failed to detect those below 0.6 mm using a routine protocol. EID‐CT with Qr54 improved visibility but distorted boundaries. Calcifications were less visible on EID‐CT than PCD‐CT as phantom sizes increased. 0.6‐ and 0.7‐mm calcified fragments were barely visible on 35‐ and 40‐cm phantom EID‐CT images. Patient cases showed small calcifications missed on EID‐CT but detected on PCD‐CT.ConclusionAt matched radiation dose, PCD‐CT in UHR mode provided higher spatial resolution and improved the detectability of small calcified fragments for different phantom/patient sizes in comparison to EID‐CT.

Funder

National Institutes of Health

Publisher

Wiley

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3