Abstract

ABSTRACTBackgroundA power injector is typically employed to deliver a contrast agent to a subject (e.g., humans, animals, phantoms) during MRI, but it is costly and cannot inject more than one subject at a time. Conventional syringe pumps housing multiple syringes are typically non‐MRI compatible and, thus, should be placed outside the MRI room.PurposeTo develop the prototype of a cost‐effective, easy‐to‐use, reliable syringe pump that could be deployed inside a clinical MRI bore and operated on during a scan.MethodsThe MRI‐compatible syringe pump (MSP) was designed using Solidworks 3D modeling software and fabricated using a Raise3D Pro2 Printer. The MSP was designed to infuse up to three syringes simultaneously. The injection speed was mainly controlled with different gear sets in the escapement unit and further adjusted by changing the effective hairspring length via a pinch pin. The MSP was evaluated with three gear sets (gear ratios: 0.20:1, 0.56:1, and 1.09:1) and 10 different effective hairspring lengths at each gear ratio. A video was recorded while operating MSP at each injection speed to calculate the volume injection rate of a 5‐mL syringe (mL/s). The MSP was operated five times repeatedly at each injection speed, and the mean and standard deviation of the volume injection rate were calculated.ResultsThe volume injection rates produced by three gear ratios (0.20:1, 0.56:1, and 1.09:1) were 0.209 ± 0.003 mL/s, 0.411 ± 0.002 mL/s, and 0.625 ± 0.006 mL/s, respectively, at the full hairspring length. The injection rates of gear set 1 (gear ratio: 0.20:1) decreased from 0.273 ± 0.001 mL/s to 0.245 ± 0.001 mL/s with a decrement of 0.003 mL/s for 10 different effective hairspring lengths (r = 0.997, p < 0.001). The injection rates of gear set 2 (gear ratio: 0.56:1) decreased from 0.519 ± 0.003 mL/s to 0.469 ± 0.003 mL/s with a decrement of 0.006 mL/s (r = 0.987, p < 0.001), and that of gear set 3 (gear ratio: 1.09:1) decreased from 0.779 ± 0.012 mL/s to 0.709 ± 0.005 mL/s with a decrement of 0.007 mL/s (r = 0.963, p < 0.001). The coefficient of variation in the injection rate measurement was 0.727 ± 0.346%.ConclusionsThe MSP is a portable device that can reliably deliver a liquid agent to multiple subjects inside a clinical MRI bore during a scan.

Funder

National Cancer Institute

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3