Evaluation of a two‐dimensional Moire‐free antiscatter grid for cone‐beam computed tomography

Author:

Kim Jongkuk1,Kang Yoonseok1,Hwang Taesoon1,Park Myungkyu1,Chung Woohyun1

Affiliation:

1. Department of Grid Research and Development JPI Healthcare, Co., Ltd. Ansan‐si Gyeonggi‐do Republic of Korea

Abstract

AbstractBackgroundScatter radiation is a traditional problem in cone‐beam computed tomography (CBCT). Accordingly, numerous methods have been researched for scatter reduction in terms of software‐ or hardware‐based solutions. The concept of a two‐dimensional antiscatter grid (2D‐ASG) has been shown to provide a solution to the scatter reduction in CBCT. However, the use of an ASG makes it challenging to use in clinical CBCT systems because it causes Moire artifacts of the image.PurposeWe have developed a Moire‐free 2D‐ASG that was designed to solve the Moire artifact and the scatter radiation problems. We provide the experimental results pertaining to the image quality measurements from the evaluation of the 2D‐ASG compared with those obtained from a one‐dimensional antiscatter grid (1D‐ASG) and no antiscatter grid (No‐ASG) to demonstrate the quantitative extent of the improvements.MethodsThe 2D‐ASG, fabricated based on a sawing process with a graphite body, was prepared to evaluate image quality improvements. Projection images for Pro‐CT MK II phantom were acquired using the CBCT testbed of sample rotation type and reconstructed by Feldkamp–Davis–Kress (FDK) algorithm without any filters. We measured the contrast‐to‐noise ratio (CNR) and uniformity index for the cupping artifacts of the 2D‐ASG, 1D‐ASG, and No‐ASG cases.Results2D‐ASG considerably reduced the cupping artifacts owing to the scatter reduction compared with the 1D‐ASG and No‐ASG cases. The cupping artifacts were reduced by 85% in the 2D‐ASG compared with No‐ASG, while the cupping artifacts were reduced by 63% in 1D‐ASG compared with No‐ASG. The 2D‐ASG also yielded a CNR improvement. The average CNR improvements for eight insert materials were 47% in the 2D‐ASG compared with No‐ASG, while the CNR was improved by 36% in the 1D‐ASG compared with No‐ASG.ConclusionsWe demonstrated that the Moire‐free 2D‐ASG improved the image quality by removing scatter radiation in CBCT compared with 1D‐ASG and No‐ASG. We believe that the Moire‐free 2D‐ASG can become one of the effective ways to solve the scatter radiation problem in CBCT images because it provides usability and has the potential to have synergistic effects on other methods, such as bow‐tie filter and scatter correction.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3