Standardization of flow cytometric detection of antigen expression

Author:

Tian Linhua1,Nelson Aaron R.2,Lowe Tyler2,Weaver Linda2,Yuan Constance2ORCID,Wang Hao‐Wei2ORCID,DeRose Paul1,Stetler‐Stevenson Maryalice2,Wang Lili1

Affiliation:

1. Biosystems and Biomaterials Division National Institute of Standards and Technology (NIST) Gaithersburg Maryland USA

2. Laboratory of Pathology National Cancer Institute, National Institutes of Health Bethesda Maryland USA

Abstract

AbstractSince response to antigen‐based immunotherapy relies upon the level of tumor antigen expression we developed an antigen quantification assay using ABC values. Antigen quantification as a clinical assay requires methods for quality control and for interlaboratory and inter‐cytometer platform standardization. A single lot of Cytotrol™ Lyophilized Control Cells (Beckman Coulter) used for all studies. The variability in antigen quantification across 4 different instrument platforms in 2 separate laboratories was evaluated. The effect of the antibody clone utilized, importance of custom 1:1 molar ratio (fluorophore to protein, F/P) verses off‐the‐shelf antibodies, and QuantiBrite PE calibration verses linearity calibration combined with a single point scale transformation with CD4 as reference were determined. Use of single lot control cells allowed validation of reproducibility between flow cytometer platforms and laboratories and allowed assessment of different antibody lots, cocktail preparation, and different antibody clones. Off the shelf antibody preparations provide reproducible estimates of antigen density, however custom 1:1 unimolar antibody preparations should be utilized for definitive measurement of antigen expression.Geometric Mean fluorescent Intensity (GeoMFI) was not comparable across instruments and inter‐laboratory. The use of CD4 as the reference marker can minimize variability in ABC values. Comparable antigen quantification is vital in managing patients receiving antigen‐based immunotherapy. If this assay is to be utilized in a clinical setting, quality control methods have to be instituted to assure reproducibility and allow validation across laboratories. We have demonstrated that use of a lyophilized cell control is highly valuable in achieveing these goals.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Issue highlights—February 2024;Cytometry Part B: Clinical Cytometry;2024-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3