Concurrent Validity of a Low‐Cost Manometer for Objective Assessments of Respiratory Muscle Strength

Author:

Curtis James A.12ORCID,Mocchetti Valentina2,Rameau Anaïs23ORCID

Affiliation:

1. Aerodigestive Innovations Research Lab (AIR), Department of Otolaryngology‐Head & Neck Surgery Weill Cornell Medical College New York New York U.S.A.

2. Department of Otolaryngology‐Head & Neck Surgery, Sean Parker Institute for the Voice Weill Cornell Medicine New York New York U.S.A.

3. Laryngology Innovation Lab, Department of Otolaryngology‐Head & Neck Surgery Weill Cornell Medical College New York New York U.S.A.

Abstract

Objective(s)This study examined the agreement in maximal expiratory (MEP) and inspiratory (MIP) pressure readings between two digital manometers: (1) the MicroRPM – the gold‐standard manometer for respiratory muscle strength testing; and (2) the LDM – a low‐cost, commercially available, alternative manometer.MethodsPositive (MEP) and negative (MIP) pressures were simultaneously applied to the MicroRPM and LDM using a 3‐liter syringe within a controlled laboratory setting. Pressure readings were compared, and agreement was analyzed using Lin's concordance correlation (ρc). Agreement was interpreted as ‘poor’ if <0.90, ‘moderate’ if 0.90 – <0.95, ‘substantial’ if 0.95 – <0.99, and ‘excellent’ if ≥0.99. Twenty percent of the pressure trials were repeated by a second researcher to examine test–retest reliability.ResultsA total of 150 trials were completed, ranging from −167 to +208 cmH2O. There was a median absolute difference of 0.3 cmH2O in pressure readings between the MicroRPM and the LDM. Lin's concordance correlation revealed ‘excellent’ agreement between the LDM and MicroRPM devices, with test–retest reliability assessment revealing ‘substantial‐to‐excellent’ agreement between the LDM and MicroRPM devices, with a concordance correlation coefficient of ρc = 0.999 (95% CI: 0.999–0.999).ConclusionsThere was a median difference of 1.0% in MEP and MIP pressure readings consistently observed between the LDM and MicroRPM. Despite these relatively small differences, excellent agreement between the two manometers was present. These data suggest the LDM may be a valid, lower cost alternative to the MicroRPM for objectively assessing respiratory strength in clinical practice; however, additional research is needed in healthy adults and in patient populations.Level of EvidenceN/A Laryngoscope, 2023

Funder

National Institute on Aging

Common Fund

Publisher

Wiley

Subject

Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3