Effect of singular value decomposition on removing injection variability in 2D quantitative angiography: An in silico and in vitro phantoms study

Author:

Mondal Parmita12,Setlur Nagesh Swetadri Vasan23,Sommers‐Thaler Sam12,Shields Allison12,Shiraz Bhurwani Mohammad Mahdi4,Williams Kyle A.12,Baig Ammad23,Snyder Kenneth23,Siddiqui Adnan H.23,Levy Elad23,Ionita Ciprian N.1234

Affiliation:

1. Department of Biomedical Engineering University at Buffalo Buffalo New York USA

2. Canon Stroke and Vascular Research Center Buffalo New York USA

3. University at Buffalo Neurosurgery, Inc Buffalo New York USA

4. Quantitative Angiographic Systems. Artificial Intelligence Buffalo New York USA

Abstract

AbstractBackgroundIntraoperative 2D quantitative angiography (QA) for intracranial aneurysms (IAs) has accuracy challenges due to the variability of hand injections. Despite the success of singular value decomposition (SVD) algorithms in reducing biases in computed tomography perfusion (CTP), their application in 2D QA has not been extensively explored. This study seeks to bridge this gap by investigating the potential of SVD‐based deconvolution methods in 2D QA, particularly in addressing the variability of injection durations.PurposeBuilding on the identified limitations in QA, the study aims to adapt SVD‐based deconvolution techniques from CTP to QA for IAs. This adaptation seeks to capitalize on the high temporal resolution of QA, despite its two‐dimensional nature, to enhance the consistency and accuracy of hemodynamic parameter assessment. The goal is to develop a method that can reliably assess hemodynamic conditions in IAs, independent of injection variables, for improved neurovascular diagnostics.Materials and methodsThe study included three internal carotid aneurysm (ICA) cases. Virtual angiograms were generated using computational fluid dynamics (CFD) for three physiologically relevant inlet velocities to simulate contrast media injection durations. Time‐density curves (TDCs) were produced for both the inlet and aneurysm dome. Various SVD variants, including standard SVD (sSVD) with and without classical Tikhonov regularization, block‐circulant SVD (bSVD), and oscillation index SVD (oSVD), were applied to virtual angiograms. The method was applied on virtual angiograms to recover the aneurysmal dome impulse response function (IRF) and extract flow related parameters such as Peak Height PHIRF, Area Under the Curve AUCIRF, and Mean transit time MTT. Next, correlations between QA parameters, injection duration, and inlet velocity were assessed for unconvolved and deconvolved data for all SVD methods. Additionally, we performed an in vitro study, to complement our in silico investigation. We generated a 2D DSA using a flow circuit design for a patient‐specific internal carotid artery phantom. The DSA showcases factors like x‐ray artifacts, noise, and patient motion. We evaluated QA parameters for the in vitro phantoms using different SVD variants and established correlations between QA parameters, injection duration, and velocity for unconvolved and deconvolved data.ResultsThe different SVD algorithm variants showed strong correlations between flow and deconvolution‐adjusted QA parameters. Furthermore, we found that SVD can effectively reduce QA parameter variability across various injection durations, enhancing the potential of QA analysis parameters in neurovascular disease diagnosis and treatment.ConclusionImplementing SVD‐based deconvolution techniques in QA analysis can enhance the precision and reliability of neurovascular diagnostics by effectively reducing the impact of injection duration on hemodynamic parameters.

Funder

National Science Foundation

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3