Performance of single‐gene noninvasive prenatal testing for autosomal recessive conditions in a general population setting

Author:

Wynn Julia1ORCID,Hoskovec Jennifer1ORCID,Carter Rebecca D.1,Ross Meredith J.1,Perni Sriram C.2

Affiliation:

1. BillionToOne, Inc Menlo Park California USA

2. Department of Obstetrics and Gynecology Bon Secours Mercy Health Mercy St. Vincent Medical Center Toledo Ohio USA

Abstract

AbstractObjectiveCarrier screening with reflex to single‐gene noninvasive prenatal testing (sgNIPT) is an alternative approach for identifying pregnancies at risk for inherited autosomal recessive conditions without the need for a sample from the reproductive partner. This study is the largest clinical validation of this approach in a general population setting.MethodsThe clinical performance of carrier screening with reflex to sgNIPT for cystic fibrosis, spinal muscular atrophy, alpha thalassemias, and beta hemoglobinopathies was assessed by collecting pregnancy outcome data on patients who underwent this testing and comparing the neonatal outcome to the assay‐predicted fetal risk.ResultsOf 42,067 pregnant individuals who underwent screening, 7538 carriers (17.9%) had reflex sgNIPT, and neonatal or fetal outcomes were obtained for 528 cases, including 25 affected pregnancies. Outcomes demonstrated high concordance with sgNIPT, for example, all pregnancies with 9 in 10 personalized fetal risk results were affected (positive predictive value (PPV) of 100% for the sub‐group) and the sgNIPT assay showed a sensitivity of 96.0% (95% CI: 79.65%–99.90%), specificity of 95.2% (95% CI: 92.98%–96.92%), average PPV of 50.0% (95% CI: 35.23%–64.77%), and negative predictive value (NPV) of 99.8% (95% CI: 98.84%–99.99%). The end‐to‐end performance of carrier screening with reflex to sgNIPT was calculated to have a sensitivity of 92.4% and specificity of 99.9%, which are unaffected by partner carrier screening or misattributed paternity unlike a traditional carrier screening workflow, which has a 35% sensitivity and a maximum of 25% PPV (1 in 4) in a real‐life setting.ConclusionThis study builds upon earlier findings to confirm that carrier testing with reflex to sgNIPT is highly accurate for general population screening. Given this high accuracy and an NPV of 99.8%, this workflow should be considered as an option for most of the general pregnant population. When the biological partner sample is unavailable, this workflow should be recommended as the first‐line approach.

Publisher

Wiley

Subject

Genetics (clinical),Obstetrics and Gynecology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3