Evaluating O2 : Ar, N2 : Ar, and 29,30N2 using membrane inlet mass spectrometry configured to minimize oxygen interference

Author:

Boedecker Ashlynn R.12ORCID,Taylor Jason M.3,Tappenbeck Tyler H.4,Hall Robert O.4,Robbins Caleb J.12ORCID,Scott J. Thad12ORCID

Affiliation:

1. Department of Biology Baylor University Waco Texas USA

2. Center for Reservoir and Aquatic Systems Research Baylor University Waco Texas USA

3. Water Quality and Ecology Research Unit, Agricultural Research Service, United States Department of Agriculture Oxford Mississippi USA

4. Flathead Lake Biological Station, University of Montana Polson Montana USA

Abstract

AbstractMembrane inlet mass spectrometry (MIMS) provides detailed measures of dissolved 28,29,30N2, O2, and argon (Ar) for estimating important gas fluxes and concentrations in aquatic ecosystems. Previous studies demonstrated a large O2 scavenging effect while using a MIMS, where varying concentrations of O2 can affect measured N2 : Ar because O2 interacts with N2 in the ion source to produce NO+ (m/z = 30), potentially decreasing the detected current for 28,29N2 and increasing the detected current for 30N2. A common solution is to use a muffle furnace heated to 600°C with a copper reduction column to reduce the concentration of O2 to minimal levels and accurately measure 28,29,30N2. However, this solution eliminates the detection of O2 in environmental samples, which is a major benefit of using a MIMS. We questioned whether the MIMS was sensitive enough to provide accurate O2 estimates when using the furnace and whether the O2 scavenging effect was real and consistent among MIMS. We conducted four separate experiments on three different MIMS to test the O2 scavenging effect and the potential detection of O2 when using a MIMS with furnace. The furnace removed ~ 99% of O2, and O2 scavenging had little to no detectable effect on N2 : Ar and an unclear effect on 29N2 : 28N2, but increased 30N2 : 28N2. In most cases, accurate O2 data could be retrieved despite using the furnace. The need for O2 reduction may be limited to measuring accurate 30N2 : 28N2 in isotope pairing studies, but without substantial loss of MIMS measurements used to describe O2 dynamics.

Funder

Office of Science

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3