Development of a fast‐response system with integrated calibration for high‐resolution mapping of dissolved methane concentration in surface waters

Author:

Dugan Jesse T.1ORCID,Weber Thomas1,Kessler John D.1

Affiliation:

1. Department of Earth and Environmental Sciences University of Rochester Rochester New York USA

Abstract

AbstractDissolved gas concentrations in surface waters can have sharp gradients across marine and freshwater environments, which often prove challenging to capture with analytical measurement. Collecting discrete samples for laboratory analysis provides accurate results, but suffers from poor spatial resolution. To overcome this limitation, water equilibrators and gas membrane contactors (GMCs) have been used for the automated underway measurement of dissolved gas concentrations in surface water. However, while water equilibrators can provide continuous measurements, their analytical response times to changes in surface water concentration can be slow, lasting tens of minutes. This leads to spatial imprecisions in the dissolved gas concentration data. Conversely, while GMCs have proven to have much faster analytical response times, often lasting only a few minutes or less, they suffer from poor accuracy and thus require routine calibration. Here we present an analytical system for the high accuracy and high precision spatial mapping of dissolved methane concentration in surface waters. The system integrates a GMC with a cavity ringdown spectrometer for fast analytical response times, with a calibration method involving two Weiss‐style equilibrators and discrete measurements in vials. Data from both the GMC and equilibrators are collected simultaneously, with discrete vial samples collected periodically throughout data collection. We also present a mathematical algorithm integrating all data collected for the routine calibration of the GMC dataset. The algorithm facilitates comparison between the GMC and equilibrator datasets despite the substantial differences in response times (0.7–2.1 and 4.1–17.6 min, respectively). This measurement system was tested with both systematic laboratory experiments and field data collected on a research cruise along the US Atlantic margin. Once calibrated, this system identified numerous sharp peaks of dissolved methane concentration in the US Atlantic margin dataset that would be poorly resolved, or outright missed with previous measurement techniques. Overall, the precision and accuracy for the technique presented here were determined to be 11.2% and 10.4%, respectively, the operating range was 0–1000 ppm methane, and the e‐folding response time to changes in dissolved methane concentration was 0.7–2.1 min.

Funder

National Science Foundation

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3