Experimental study on synthetic and biological mesh implantation in a contaminated environment

Author:

Deerenberg E B1,Mulder I M1,Grotenhuis N12,Ditzel M1,Jeekel J3,Lange J F1

Affiliation:

1. Department of Surgery, Erasmus University Medical Centre, Rotterdam, The Netherlands

2. Department of Otorhinolaryngology, Erasmus University Medical Centre, Rotterdam, The Netherlands

3. Department of Neuroscience, Erasmus University Medical Centre, Rotterdam, The Netherlands

Abstract

Abstract Background Implantation of meshes in a contaminated environment can be complicated by mesh infection and adhesion formation. Methods The caecal ligation and puncture model was used to induce peritonitis in 144 rats. Seven commercially available meshes were implanted intraperitoneally: six non-absorbable meshes, of which three had an absorbable coating, and one biological mesh. Mesh infection, intra-abdominal abscess formation, adhesion formation, incorporation and shrinkage were evaluated after 28 and 90 days. Histological examination with haematoxylin and eosin and picrosirius red staining was performed. Results No mesh infections occurred in Sepramesh®, Omyramesh® and Strattice®. One mesh infection occurred in Parietene® and Parietene Composite®. Significantly more mesh infections were found in C-Qur® (15 of 16; P ≤ 0·006) and Dualmesh® (7 of 15; P ≤ 0·035). Sepramesh® showed a significant increase in adhesion coverage from 12·5 per cent at 28 days to 60·0 per cent at 90 days (P = 0·010). At 90 days there was no significant difference between median adhesion coverage of Parietene Composite® (35·0 per cent), Omyramesh® (42·5 per cent), Sepramesh® (60·0 per cent) and Parietene® (72·5 per cent). After 90 days the adhesion coverage of Strattice® was 5·0 per cent, and incorporation (13·4 per cent) was significantly poorer than for other non-infected meshes (P ≤ 0·009). Dualmesh® showed shrinkage of 63 per cent after 90 days. Conclusion Parietene Composite® and Omyramesh® performed well in a contaminated environment. Strattice® had little adhesion formation and no mesh infection, but poor incorporation. Some synthetic meshes can be as resistant to infection as biological meshes.

Publisher

Oxford University Press (OUP)

Subject

Surgery

Cited by 34 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司