Feasibility of bone marrow edema detection using dual‐energy cone‐beam computed tomography

Author:

Liu Stephen Z.1,Herbst Magdalena2,Schaefer Jamin2,Weber Thomas2,Vogt Sebastian2,Ritschl Ludwig2,Kappler Steffen2,Kawcak Christopher E.3,Stewart Holly L.3,Siewerdsen Jeffrey H.14,Zbijewski Wojciech1

Affiliation:

1. Department of Biomedical Engineering Johns Hopkins University Baltimore Maryland USA

2. Siemens Healthineers Forchheim Germany

3. Department of Clinical Sciences Colorado State University College of Veterinary Medicine and Biomedical Sciences Fort Collins Colorado USA

4. Department of Imaging Physics MD Anderson Cancer Center Houston Texas USA

Abstract

AbstractBackgroundDual‐energy (DE) detection of bone marrow edema (BME) would be a valuable new diagnostic capability for the emerging orthopedic cone‐beam computed tomography (CBCT) systems. However, this imaging task is inherently challenging because of the narrow energy separation between water (edematous fluid) and fat (health yellow marrow), requiring precise artifact correction and dedicated material decomposition approaches.PurposeWe investigate the feasibility of BME assessment using kV‐switching DE CBCT with a comprehensive CBCT artifact correction framework and a two‐stage projection‐ and image‐domain three‐material decomposition algorithm.MethodsDE CBCT projections of quantitative BME phantoms (water containers 100–165 mm in size with inserts presenting various degrees of edema) and an animal cadaver model of BME were acquired on a CBCT test bench emulating the standard wrist imaging configuration of a Multitom Rax twin robotic x‐ray system. The slow kV‐switching scan protocol involved a 60 kV low energy (LE) beam and a 120 kV high energy (HE) beam switched every 0.5° over a 200° angular span. The DE CBCT data preprocessing and artifact correction framework consisted of (i) projection interpolation onto matched LE and HE projections views, (ii) lag and glare deconvolutions, and (iii) efficient Monte Carlo (MC)‐based scatter correction. Virtual non‐calcium (VNCa) images for BME detection were then generated by projection‐domain decomposition into an Aluminium (Al) and polyethylene basis set (to remove beam hardening) followed by three‐material image‐domain decomposition into water, Ca, and fat. Feasibility of BME detection was quantified in terms of VNCa image contrast and receiver operating characteristic (ROC) curves. Robustness to object size, position in the field of view (FOV) and beam collimation (varied 20–160 mm) was investigated.ResultsThe MC‐based scatter correction delivered > 69% reduction of cupping artifacts for moderate to wide collimations (> 80 mm beam width), which was essential to achieve accurate DE material decomposition. In a forearm‐sized object, a 20% increase in water concentration (edema) of a trabecular bone‐mimicking mixture presented as ∼15 HU VNCa contrast using 80–160 mm beam collimations. The variability with respect to object position in the FOV was modest (< 15% coefficient of variation). The areas under the ROC curve were > 0.9. A femur‐sized object presented a somewhat more challenging task, resulting in increased sensitivity to object positioning at 160 mm collimation. In animal cadaver specimens, areas of VNCa enhancement consistent with BME were observed in DE CBCT images in regions of MRI‐confirmed edema.ConclusionOur results indicate that the proposed artifact correction and material decomposition pipeline can overcome the challenges of scatter and limited spectral separation to achieve relatively accurate and sensitive BME detection in DE CBCT. This study provides an important baseline for clinical translation of musculoskeletal DE CBCT to quantitative, point‐of‐care bone health assessment.

Funder

National Institutes of Health

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3