Improving 3D dose prediction for breast radiotherapy using novel glowing masks and gradient‐weighted loss functions

Author:

Moore Lance C.1,Nematollahi Fatemeh1,Li Lingyi1,Meyers Sandra M.1,Kisling Kelly1

Affiliation:

1. Radiation Medicine and Applied Sciences University of California La Jolla San Diego California USA

Abstract

AbstractBackgroundThe quality of treatment plans for breast cancer can vary greatly. This variation could be reduced by using dose prediction to automate treatment planning. Our work investigates novel methods for training deep‐learning models that are capable of producing high‐quality dose predictions for breast cancer treatment planning.PurposeThe goal of this work was to compare the performance impact of two novel techniques for deep learning dose prediction models for tangent field treatments for breast cancer. The first technique, a “glowing” mask algorithm, encodes the distance from a contour into each voxel in a mask. The second, a gradient‐weighted mean squared error (MSE) loss function, emphasizes the error in high‐dose gradient regions in the predicted image.MethodsFour 3D U‐Net deep learning models were trained using the planning CT and contours of the heart, lung, and tumor bed as inputs. The dataset consisted of 305 treatment plans split into 213/46/46 training/validation/test sets using a 70/15/15% split. We compared the impact of novel “glowing” anatomical mask inputs and a novel gradient‐weighted MSE loss function to their standard counterparts, binary anatomical masks, and MSE loss, using an ablation study methodology. To assess performance, we examined the mean error and mean absolute error (ME/MAE) in dose across all within‐body voxels, the error in mean dose to heart, ipsilateral lung, and tumor bed, dice similarity coefficient (DSC) across isodose volumes defined by 0%–100% prescribed dose thresholds, and gamma analysis (3%/3 mm).ResultsThe combination of novel glowing masks and gradient weighted loss function yielded the best‐performing model in this study. This model resulted in a mean ME of 0.40%, MAE of 2.70%, an error in mean dose to heart and lung of −0.10 and 0.01 Gy, and an error in mean dose to the tumor bed of −0.01%. The median DSC at 50/95/100% isodose levels were 0.91/0.87/0.82. The mean 3D gamma pass rate (3%/3 mm) was 93%.ConclusionsThis study found the combination of novel anatomical mask inputs and loss function for dose prediction resulted in superior performance to their standard counterparts. These results have important implications for the field of radiotherapy dose prediction, as the methods used here can be easily incorporated into many other dose prediction models for other treatment sites. Additionally, this dose prediction model for breast radiotherapy has sufficient performance to be used in an automated planning pipeline for tangent field radiotherapy and has the major benefit of not requiring a PTV for accurate dose prediction.

Funder

National Institutes of Health

National Science Foundation

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3