Reduced B0/B1+ sensitivity in velocity‐selective inversion arterial spin labeling using adiabatic refocusing pulses

Author:

Bolar Divya S.12ORCID,Barnes Ryan A.12,Chen Conan123,Han Fei4,Pfeuffer Josef5,Liu Thomas T.126ORCID,Wong Eric C.126

Affiliation:

1. Center for Functional MRI University of California San Diego La Jolla California USA

2. Department of Radiology University of California San Diego La Jolla California USA

3. Department of Electrical and Computer Engineering University of California San Diego La Jolla California USA

4. Siemens Medical Solutions Malvern Pennsylvania USA

5. Application Development, Siemens Healthineers AG Erlangen Germany

6. Department of Psychiatry University of California San Diego La Jolla California USA

Abstract

AbstractPurposeTo mitigate the B0/B1+ sensitivity of velocity‐selective inversion (VSI) pulse trains for velocity‐selective arterial spin labeling (VSASL) by implementing adiabatic refocusing. This approach aims to achieve artifact‐free VSI‐based perfusion imaging through single‐pair label‐control subtractions, reducing the need for the currently required four‐pair dynamic phase‐cycling (DPC) technique when using a velocity‐insensitive control.MethodsWe introduce a Fourier‐transform VSI (FT‐VSI) train that incorporates sinc‐modulated hard excitation pulses with MLEV‐8‐modulated adiabatic hyperbolic secant refocusing pairs. We compare performance between this train and the standard composite refocusing train, including with and without DPC, for dual‐module VSI VSASL. We evaluate (1) simulated velocity‐selective profiles and subtraction fidelity across a broad B0/B1+ range, (2) subtraction fidelity in phantoms, and (3) image quality, artifact presence, and gray‐matter perfusion heterogeneity (as measured by the spatial coefficient of variation) in healthy human subjects.ResultsAdiabatic refocusing significantly improves FT‐VSI robustness to B0/B1+ inhomogeneity for a single label‐control subtraction. Subtraction fidelity is dramatically improved in both simulation and phantoms compared with composite refocusing without DPC, and is similar compared with DPC methods. In humans, marked artifacts seen with the non‐DPC composite refocusing approach are eliminated, corroborated by significantly reduced gray‐matter heterogeneity (via lower spatial coefficient of variation values).ConclusionA novel VSASL labeling train using adiabatic refocusing pulses for VSI was found to reduce artifacts related to B0/B1+ inhomogeneity, thereby providing an alternative to DPC and its associated limitations, which include increased vulnerability to physiological noise and motion, reduced functional MRI applicability, and suboptimal data censoring.

Funder

Siemens Medical Solutions USA

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3