Temporary balloon occlusion test can overestimate the risk of acute pulmonary edema after transcatheter atrial septal defect closure

Author:

Nakagawa Koji1ORCID,Akagi Teiji2ORCID,Takaya Yoichi1ORCID,Miki Takashi1ORCID,Kijima Yasufumi3,Nakayama Rie1,Toh Norihisa1ORCID,Nishii Nobuhiro4,Nakamura Kazufumi1,Morita Hiroshi4,Ito Hiroshi1

Affiliation:

1. Department of Cardiovascular Medicine, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Okayama University Okayama Japan

2. Cardiac Intensive Care Unit Okayama University Hospital Okayama Japan

3. Department of Cardiovascular Medicine St. Luke's International Hospital Tokyo Japan

4. Department of Cardiovascular Therapeutics, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Okayama University Okayama Japan

Abstract

AbstractBackgroundAtrial septal defect (ASD) closure can cause acute pulmonary edema. Before transcatheter closure is performed, temporary balloon occlusion test (BOT) is recommended in patients with left ventricular dysfunction to predict the risk of pulmonary edema. However, the accuracy of BOT has not been verified. This study aimed to compare hemodynamic differences between BOT and transcatheter closure.MethodsA total of 42 patients with a single ASD over age 18 years who underwent BOT before transcatheter ASD closure between October 2010 and May 2020 were analyzed. Pulmonary capillary wedge pressure (PCWP) was measured using a Swan−Ganz catheter placed in the pulmonary artery at baseline, after 10 min of BOT, and after transcatheter closure. Amplatzer septal occluder was used for all transcatheter closures.ResultsMean patient age was 64 ± 18 years (range, 18−78). Mean ASD diameter and pulmonary to systemic flow ratio were 18 ± 5 and 2.8 ± 1.0 mm, respectively. Mean PCWP at baseline, during BOT, and after transcatheter closure was 8.9 ± 2.9, 13.5 ± 4.2, and 9.5 ± 2.6 mmHg, respectively. The difference between BOT and after transcatheter closure values was significant (p < 0.001). During BOT, PCWP increased ≥18 mmHg in 7 patients, whereas after ASD closure, PCWP was <18 mmHg in all 7 and none developed acute pulmonary edema.ConclusionTemporary balloon occlusion of an ASD and transcatheter ASD closure result in different hemodynamic change. BOT overestimates increase of PCWP after transcatheter ASD closure and requires careful interpretation. Well‐designed, larger studies in higher‐risk patients are warranted to verify the clinical implications of BOT in more detail.

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine

Reference13 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3