Comparison of baseline correction algorithms for in vivo 1H‐MRS

Author:

Pasmiño Diego1,Slotboom Johannes2ORCID,Schweisthal Brigitte23,Guevara Pamela1,Valenzuela Waldo2,Pino Esteban J.1

Affiliation:

1. Electrical Engineering Department Universidad de Concepcion Concepcion Chile

2. Support Center for Advanced Neuroimaging (SCAN), Neuroradiology University Hospital Inselspital Bern Switzerland

3. Politehnica University Timișoara Timișoara Romania

Abstract

Proton MRS is used clinically to collect localized, quantitative metabolic data from living tissues. However, the presence of baselines in the spectra complicates accurate MRS data quantification. The occurrence of baselines is not specific to short‐echo‐time MRS data. In short‐echo‐time MRS, the baseline consists typically of a dominating macromolecular (MM) part, and can, depending on B0 shimming, poor voxel placement, and/or localization sequences, also contain broad water and lipid resonance components, indicated by broad components (BCs). In long‐echo‐time MRS, the MM part is usually much smaller, but BCs may still be present. The sum of MM and BCs is denoted by the baseline. Many algorithms have been proposed over the years to tackle these artefacts. A first approach is to identify the baseline itself in a preprocessing step, and a second approach is to model the baseline in the quantification of the MRS data themselves. This paper gives an overview of baseline handling algorithms and also proposes a new algorithm for baseline correction. A subset of suitable baseline removal algorithms were tested on in vivo MRSI data (semi‐LASER at TE = 40 ms) and compared with the new algorithm. The baselines in all datasets were removed using the different methods and subsequently fitted using spectrIm‐QMRS with a TDFDFit fitting model that contained only a metabolite basis set and lacked a baseline model. The same spectra were also fitted using a spectrIm‐QMRS model that explicitly models the metabolites and the baseline of the spectrum. The quantification results of the latter quantification were regarded as ground truth. The fit quality number (FQN) was used to assess baseline removal effectiveness, and correlations between metabolite peak areas and ground truth models were also examined. The results show a competitive performance of our new proposed algorithm, underscoring its automatic approach and efficiency. Nevertheless, none of the tested baseline correction methods achieved FQNs as good as the ground truth model. All separately applied baseline correction methods introduce a bias in the observed metabolite peak areas. We conclude that all baseline correction methods tested, when applied as a separate preprocessing step, yield poorer FQNs and biased quantification results. While they may enhance visual display, they are not advisable for use before spectral fitting.

Funder

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Publisher

Wiley

Reference52 articles.

1. Introduction to MR spectroscopy in vivo

2. Signal Processing in Magnetic Resonance Spectroscopy with Biomedical Applications

3. In vivo proton MR spectroscopy reveals altered metabolite content in malignant prostate tissue;Heerschap A;Anticancer Res,1997

4. Imaging in breast cancer: Magnetic resonance spectroscopy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3