Impact of skin hydration on patterns of microthermal injury produced by fractional CO2 laser

Author:

Wenande Emily1ORCID,Hastrup Anna1ORCID,Fredman Gabriella Louise1ORCID,Olesen Uffe Høgh1ORCID,Wolkerstorfer Albert2ORCID,Haedersdal Merete1ORCID

Affiliation:

1. Department of Dermatology Copenhagen University Hospital ‐ Bispebjerg Copenhagen Denmark

2. Department of Dermatology Amsterdam UMC Medical Centers Amsterdam The Netherlands

Abstract

AbstractObjectivesThe impact of skin hydration on patterns of thermal injury produced by ablative fractional lasers (AFLs) is insufficiently examined under standardized conditions. Using skin with three different hydration levels, this study assessed the effect of hydration status on microchannel dimensions generated by a fractional CO2 laser.MethodsA hydration model (hyperhydrated‐, dehydrated‐ and control) was established in ex vivo porcine skin, validated by changes in surface conductance and sample mass. After, samples underwent AFL exposure using a CO2 laser (10,600 nm) at two examined pulse energies (10 and 30 mJ/mb, fixed 10% density, six repetitions per group). Histological assessment of distinct microchannels (n = 60) determined three standardized endpoints in H&E sections: (1) depth of microthermal treatment zones (MTZs), (2) depth of microscopic ablation zones (MAZs), and (3) coagulation zone (CZ) thickness. As a supplemental in vivo assessment, the same laser settings were applied to hyperhydrated‐ (7‐h occlusion) and normohydrated forearm skin (no pretreatment) of a human volunteer. Blinded measurement of MAZ depth (n = 30) was performed using noninvasive optical coherence tomography (OCT).ResultsModest differences in microchannel dimensions were shown between hyperhydrated, dehydrated and control skin at both high and low pulse energy. Compared to controls, hyperhydration led to median reductions in MTZ and MAZ depth ranging from 5% to 8% (control vs. hyperhydrated at 30 mJ/mb; 848 vs. 797 µm (p < 0.003) (MAZ); 928 vs. 856 µm (p < 0.003) (MTZ)), while 14%–16% reductions were shown in dehydrated skin (control vs. dehydrated at 30 mJ/mb; MAZ: 848 vs. 727 µm (p < 0.003); MTZ: 928 vs. 782 µm (p < 0.003)). The impact of skin hydration on CZ thickness was in contrast limited. Corresponding with ex vivo findings, hyperhydration was similarly associated with lower ablative depth in vivo skin. Thus, median MAZ depth in hydrated skin was 10% and 14% lower than in control areas at 10 and 30 mJ/mb pulse energy, respectively (10 mJ: 210 vs. 180 µm (p < 0.001); 30 mJ: 335 vs. 300 µm (p < 0.001)).ConclusionSkin hydration status can exert a minimal impact on patterns of microthermal injury produced by fractional CO2 lasers, although the clinical implication in the context of laser therapy requires further study.

Publisher

Wiley

Subject

Dermatology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3