Clinical and experimental studies of intraoperative autotransfusion using a new filtration device

Author:

Varga Z A1,Thompson J F1,Locke-Edmunds J C1,Baird R N1,Farndon J R1

Affiliation:

1. Department of Surgery, Bristol Royal Infirmary, Bristol, UK

Abstract

Abstract The Haemocell S-350 device has recently been introduced for intraoperative autotransfusion. The system uses a novel membrane filter to process shed blood. In the first part of this study a 0.2-μm pore size filter was used in a randomized trial comparing the use of autotransfusion (n = 8) with bank blood controls (n = 9) during aortic reconstruction. This part of the trial was abandoned because of unexpected non-surgical bleeding. Bank blood requirements fell from a median of 3.0 (range 0.0-9.0) units to 1.5 (range 0.0–7.0) units when autotransfusion was used, but these patients had a greater perioperative blood loss (1791 (range 932–3104) versus 1140 (range 440–3840) ml). There was evidence of postoperative heparin excess with an activated partial thromboplastin time ratio of 1.3 (range 0.9–3.0) versus 1.0 (range 1.0–1.2) in controls and an activated clotting time of 206 (range 143–280) versus 137 (range 107–142) s. This was confirmed by raised plasma heparin levels and a prolonged thrombin time normalized by protamine. To improve performance a 0.6-μm pore size filter was studied in ten patients. Filtration efficiency doubled from 19 to 38 per cent. Electron micrographs demonstrated better filter clearance, but 44 per cent of the original concentration of heparin remained in the reinfusate. The S-350 device may be an attractive alternative to centrifugation for intraoperative autotransfusion but, until efficiency is improved, it should only be used for cardiovascular surgery when excess heparin can be reversed with protamine.

Funder

Haemocell p.l.c.

Publisher

Oxford University Press (OUP)

Subject

Surgery

Reference11 articles.

1. Membrane plasma separation: toward improved clinical operation;Werinski;Transactions of the American Society for Artificial Internal Organs,1981

2. A high efficiency membrane separator in donor plasmapheresis;Bellhouse;Transactions of the American Society for Artificial Internal Organs,1988

3. Plasma filtration through a plane microporous membrane;Malbrancq;Journal of the American Society for Artificial Internal Organs,1984

4. Separation of plasma from whole blood by membrane filtration in oscillatory flows;Stairmand;Life Support Systems,1986

5. Acute normovolaemic haemodilution in major abdominal surgery;Varga;Br J Surg,1993

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3