Affiliation:
1. Department of Surgery, St Thomas' Hospital, London SE1 7EH, UK
Abstract
Abstract
In the hope that some varieties of the post-phlebitic syndrome might be treated by implanting a preserved vein valve, studies have been made of the mechanical properties of vein valves and vein wall before and after preservation with glutaraldehyde. The ultimate tensile strength (breaking stress) and strain (extensibility) of strips of vein wall and valve leaflet were measured with a Nene tensiometer. The ultimate tensile strength of valve leaflet was found to be twice that of vein wall. Preservation in glutaraldehyde (0.2 per cent, pH 7.4, for 7 days) with valve cusps closed by a minimum head of pressure caused no change in breaking stress or extensibility.
Publisher
Oxford University Press (OUP)
Cited by
31 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献