Factors influencing bowel function after ileal pouch–anal anastomosis

Author:

Nasmyth D G1,Johnston D1,Godwin P G R2,Dixon M F3,Smith A4,Williams N S1

Affiliation:

1. The University Department of Surgery, The General Infirmary, Leeds, UK

2. The University Department of Surgery Microbiology, The General Infirmary, Leeds, UK

3. The University Department of Surgery Pathology, The General Infirmary, Leeds, UK

4. Department of Nuclear Medicine, The General Infirmary, Leeds, UK

Abstract

Abstract Seventeen patients were studied 3–31 months (median 6·4 months) after mucosal proctectomy and ileal pouch–anal anastomosis for ulcerative colitis (n = 15) or adenomatous polyposis (n = 2). Seven had a triplicated pouch, and ten a duplicated pouch. Clinical bowel function was determined by detailed questionnaire, and correlations sought between clinical end-points such as frequency of defaecation, urgency of defaecation and continence, and the results of laboratory investigations, comprising anal manometry, capacity and compliance of the pouch, completeness of emptying, faecal bacteriology and mucosal inflammation. Frequency of defaecation was found to be inversely correlated with both the capacity (rs = −0·66, P < 0·01) and the compliance (rs = −0·53, P < 0·05) of the pouch. Patients who could postpone defaecation for > 30 min had higher anal squeeze pressures (P < 0·05) than patients who had greater urgency of defaecation. Patients with perfect anal continence had higher resting anal pressure (P < 0·05) and emptied the pouch more completely (P < 0·07) than patients who experienced minor leakage. The faecal flora of the pouches showed a greater predominance of anaerobes (P < 0·01) and increased numbers of bacteroides (P < 0·01) compared with the faecal flora of ileostomies, but the changes in the flora did not correlate with any aspect of bowel function. The best clinical results (i.e. perfect continence, low frequency of defaecation and little urgency) were associated with high anal pressure and with large volume, high compliance and complete emptying of the pouch. The completeness of emptying was similar for both designs of pouch, but the capacity and compliance of triplicated pouches were greater than the capacity and compliance of duplicated J pouches (P < 0·05), and this was associated with a better clinical result in the triplicated pouches.

Publisher

Oxford University Press (OUP)

Subject

Surgery

Reference14 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3