Essentially unedited deep‐learning‐based OARs are suitable for rigorous oropharyngeal and laryngeal cancer treatment planning

Author:

Koo Jihye12,Caudell Jimmy1,Latifi Kujtim1,Moros Eduardo G.1ORCID,Feygelman Vladimir1

Affiliation:

1. Department of Radiation Oncology Moffitt Cancer Center Tampa Florida USA

2. Department of Physics University of South Florida Tampa Florida USA

Abstract

AbstractQuality of organ at risk (OAR) autosegmentation is often judged by concordance metrics against the human‐generated gold standard. However, the ultimate goal is the ability to use unedited autosegmented OARs in treatment planning, while maintaining the plan quality. We tested this approach with head and neck (HN) OARs generated by a prototype deep‐learning (DL) model on patients previously treated for oropharyngeal and laryngeal cancer. Forty patients were selected, with all structures delineated by an experienced physician. For each patient, a set of 13 OARs were generated by the DL model. Each patient was re‐planned based on original targets and unedited DL‐produced OARs. The new dose distributions were then applied back to the manually delineated structures. The target coverage was evaluated with inhomogeneity index (II) and the relative volume of regret. For the OARs, Dice similarity coefficient (DSC) of areas under the DVH curves, individual DVH objectives, and composite continuous plan quality metric (PQM) were compared. The nearly identical primary target coverage for the original and re‐generated plans was achieved, with the same II and relative volume of regret values. The average DSC of the areas under the corresponding pairs of DVH curves was 0.97 ± 0.06. The number of critical DVH points which met the clinical objectives with the dose optimized on autosegmented structures but failed when evaluated on the manual ones was 5 of 896 (0.6%). The average OAR PQM score with the re‐planned dose distributions was essentially the same when evaluated either on the autosegmented or manual OARs. Thus, rigorous HN treatment planning is possible with OARs segmented by a prototype DL algorithm with minimal, if any, manual editing.

Funder

Varian Medical Systems

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3