Development of automated region of interest selection algorithms for surface‐guided radiation therapy of breast cancer

Author:

Cui Songye1,Li Guang1ORCID,Kuo Hsiang‐Chi1,Zhao Bo1,Li Anyi1,Cerviño Laura I.1

Affiliation:

1. Department of Medical Physics Memorial Sloan Kettering Cancer Center New York USA

Abstract

AbstractTo investigate automation of the preparation of the region of interest (ROI) for surface‐guided radiotherapy (SGRT) of the whole breast with two algorithms based on contour anatomies: using the body contour, and using the breast contour. The patient dataset used for modeling consisted of 39 breast cancer patients previously treated with SGRT. The patient's anatomical structures (body and ipsilateral breast) were retrieved from the planning system, and the clinical ROI (cROI) drawn by the planners was retrieved from the SGRT system for comparison. For the body‐contour‐based algorithm, a convolutional neural network (MobileNet‐v2) was utilized to train a synthetic human model dataset to predict body joint locations. With the body joint location knowledge, an automated ROI (aROIbody) can be created based on: (1) the superior‐inferior (S‐I) borders defined by the joint locations, (2) the left‐right (L‐R) borders defined with 3/4 of chest width, and (3) a curation of the ROI to avoid the ipsilateral armpit. For the breast‐contour‐based algorithm, an aROIbreast was created by first defining the ROI in the S‐I direction with the ipsilateral breast boundaries. Other steps are the same as with the body‐contour‐based algorithm. Among the 39 patients, 24 patients were used to fine‐tune the algorithm parameters, and the remaining 15 patients were used to evaluate the quality of the aROIs against the cROIs. A blinded evaluation was performed by three SGRT expert physicists to rate the acceptability and the quality (1–10 scale) of the aROIs and cROIs, and the dice similarity coefficient (DSC) was also calculated to compare the similarity between the aROIs and cROIs. The results showed that the average acceptability was 14/15 (range: 13/15–15/15) for cROIs, 13.3/15 (range: 13/15–14/15) for aROIbody, and 14.6/15 (range: 14/15–15/15) for aROIbreast. The average quality was 7.4 ± 0.8 for cROIs, 8.1 ± 1.2 for aROIbody, and 8.2 ± 0.9 for aROIbreast. The DSC with cROIs was 0.81 ± 0.06 for aROIbody, and 0.83 ± 0.04 for aROIbreast. The ROI creation time was ∼120 s for clinical, 1.3 s for aROIbody, and 1.2 s for aROIbreast. The proposed automated algorithms can improve the ROI compliance with the SGRT protocol, with a shortened preparation time. It is ready to be integrated into the clinical workflow for automated ROI preparation.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3