Off‐isocentric VMAT technique for breast cancer: Effective dose reduction to organs at risk and its applicability based on patient anatomy

Author:

Prokofev Igor1,Salim Nidal1

Affiliation:

1. Department of Radiotherapy European Medical Center Moscow Russia

Abstract

AbstractPurposeThis study aims to explore the off‐isocentric volumetric modulated arc therapy (offVMAT) technique for breast cancer and determine its applicability based on patient anatomical parameters.MethodsWe retrospectively analyzed 44 breast cancer patients with varied lymph node involvement using different arc designs. Off‐isocentric techniques were benchmarked against previously published arc techniques: classic arcs (clVMAT), tangential arcs (tVMAT), and split arcs (spVMAT). During optimization, target coverage was made for all plans as close as possible to the criteria D99% > 95% and Dmax < 110% of the prescribed dose. A novel patient categorization, based on anatomical parameters (auxiliary structures) rather than lymph node involvement, is introduced. This categorization considers the volume of ipsilateral organs at risk (OARs) adjacent to the target. A binary regression model was developed on these anatomical parameters. It predicts the likelihood of offVMAT (P[offVMAT]) achieving better criteria.ResultsUsing the regression model, patients were divided into two groups: P(offVMAT) > 0.5 and P(offVMAT) < 0.5. For the P(offVMAT) > 0.5 group, most tVMAT plans are unable to achieve the clinical objectives. Comparing offVMAT with spVMAT, offVMAT exhibited better dose parameters for the heart (V20, V10, and D2 are 7.1, 2.4, and 1.5 times lower respectively), ipsilateral lung (V20, V10, V5 and the mean dose are 1.4, 1.3, 1.2, and 1.2 times lower respectively). The average doses to the contralateral side are consistent. In the P(offVMAT) < 0.5 group, the tVMAT technique showed increased doses at medium and high levels, yet reduced doses in contralateral OARs compared to spVMAT and offVMAT. spVMAT showed lower doses in the contralateral lung relative to the offVMAT technique, while clVMAT trailed in both groups. Validation of the model yielded a 90% accuracy rate.ConclusionsThe new off‐isocentric breast planning technique effectively reduces doses to ipsilateral OARs, maintaining acceptable contralateral mean doses. This technique has an advantage over other techniques for patients with intricate anatomies. It is evaluated using anatomical parameters, which are also used to build binary regression model, which shows the dependence of anatomical parameters on whether offVMAT is preferred for individual patients. Also, such anatomical parameters provide a more objective and precise comparison between different planning techniques.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3