Four‐dimensional treatment planning strategies for dynamic tumor tracking

Author:

Carpentier Emilie E.12,McDermott Ronan L.3,Camborde Marie‐Laure A.2,Karan Tania2ORCID,Bergman Alanah M.2ORCID,Mestrovic Ante2

Affiliation:

1. Department of Physics and Astronomy University of British Columbia Vancouver British Columbia Canada

2. Department of Medical Physics BC Cancer – Vancouver Vancouver British Columbia Canada

3. Radiation Oncology BC Cancer Vancouver Vancouver British Columbia Canada

Abstract

AbstractIntroductionDynamic tumor tracking (DTT) is a motion management technique where the radiation beam follows a moving tumor in real time. Not modelling DTT beam motion in the treatment planning system leaves an organ at risk (OAR) vulnerable to exceeding its dose limit. This work investigates two planning strategies for DTT plans, the “Boolean OAR Method” and the “Aperture Sorting Method,” to determine if they can successfully spare an OAR while maintaining sufficient target coverage.Materials and methodsA step‐and‐shoot intensity modulated radiation therapy (sIMRT) treatment plan was re‐optimized for 10 previously treated liver stereotactic ablative radiotherapy patients who each had one OAR very close to the target. Two planning strategies were investigated to determine which is more effective at sparing an OAR while maintaining target coverage: (1) the “Boolean OAR Method” created a union of an OAR's contours from two breathing phases (exhale and inhale) on the exhale phase (the planning CT) and protected this combined OAR during plan optimization, (2) the “Aperture Sorting Method” assigned apertures to the breathing phase where they contributed the least to an OAR's maximum dose.ResultsAll 10 OARs exceeded their dose constraints on the original plan four‐dimensional (4D) dose distributions and average target coverage was V100% = 91.3% ± 2.9% (ranging from 85.1% to 94.8%). The “Boolean OAR Method” spared 7/10 OARs, and mean target coverage decreased to V100% = 87.1% ± 3.8% (ranging from 80.7% to 93.7%). The “Aperture Sorting Method” spared 9/10 OARs and the mean target coverage remained high at V100% = 91.7% ± 2.8% (ranging from 84.9% to 94.5%).Conclusions4D planning strategies are simple to implement and can improve OAR sparing during DTT treatments. The “Boolean OAR Method” improved sparing of OARs but target coverage was reduced. The “Aperture Sorting Method” further improved sparing of OARs and maintained target coverage.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3