Technical note: Commissioning of a low‐cost system for directly 3D printed flexible bolus

Author:

Baltz Garrett C.1ORCID,Kirsner Steven M.1

Affiliation:

1. Scripps Cancer Center San Diego California USA

Abstract

AbstractPurposeTo present the commissioning process of a low‐cost solution for directly 3D printed flexible patient specific bolus.MethodsThe 3D printing solution used in this study consisted of a resin stereolithography 3D printer and a flexible curing resin. To test the dimensional accuracy of the 3D printer, rectangular cuboids with varying dimensions were 3D printed and their measured dimensions were compared to the designed dimensions. Percent Depth Dose (PDD) profiles were measured by irradiating film embedded in a 3D printed phantom made of the flexible material. A CT of the phantom was acquired and used to replicate the irradiation setup in the treatment planning system. PDDs were calculated for both the native HU of the phantom, and with the phantom HU overridden to 300 HU to match its physical density. Dosimetric agreement was characterized by comparing calculated to measured depths of R90, R80, and R50. Upon completion of the commissioning process, a bolus was 3D printed for a clinical case study for treatment of the nose.ResultsDimensional accuracy of the printer and material combination was found to be good, with all measured dimensions of test cuboids within 0.5 mm of designed. PDD measurements demonstrated the best dosimetric agreement when the material was overridden to 300 HU, corresponding to the measured physical density of the material of 1.18 g/cc. Calculated and measured depths of R90, R80, and R50 all agreed within 1 mm. The bolus printed for the clinical case was free from defects, highly conformal, and led to a clinically acceptable plan.ConclusionThe results of the commissioning measurements performed indicate that the 3D printer and material solution are suitable for clinical use. The 3D printer and material combination can provide a low‐cost solution a clinic can implement in‐house to directly 3D print flexible bolus.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3