Affiliation:
1. Radiochemistry division Bhabha Atomic Research Centre Trombay, Mumbai 400085 India
Abstract
AbstractThe present investigation deals with the development of a polyvinyl chloride (PVC) based potentiometric sensor for Eu(III) containing N,N,N’,N’‐tetrapentyl diglycolamide (TPDGA) as ionophore, 2‐nitrophenyl octylether (NPOE) as plasticizer and sodium tetraphenylborate (NaTPB) as ionic additive. The membrane with 8.7 % TPDGA, 29.7 % PVC, 59.0 % NPOE, 2.5 % NaTPB exhibited a linear response behaviour from 1.5×10−6 m to 1.1×10−2 m Eu(III) with a slope of 23.4±0.3 mV/decade and a limit of detection (LOD) of 1.2×10−6 m. The sensor showed fast response times (<5 s) and a lifetime of two months. It showed good tolerance for monovalent/divalent interfering ions and moderate/poor tolerance for trivalent ions. The membrane was characterized using photoluminesce (PL) spectroscopy which suggested NPOE can alter the nature of species in the membrane and evidence the presence of two species. The membrane can be used as an indicator electrode for the potentiometric titration of Eu(III) and in the estimation of europium in the synthetic and laboratory bearing waste which compared well with the x‐ray fluorescene (XRF) results.
Reference69 articles.
1. D. R. Lide CRC Handbook of Chemistry and Physics–Online Edition Taylor and Francis: Boca Raton FL 2006.
2. A. Stwertka A Guide to the Elements Oxford University Press 2002.
3. Separation of lanthanide fission products from nuclear fuels by extraction chromatography and cation exchange for isotope dilution mass spectrometric analysis
4.
5. Europium in the limelight
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献