An evaluation of consumer smartphones for generating bolus and surface mould applicators for radiation oncology

Author:

Bridger Corey A.12,Caraça Santos Alexandre M.123,Reich Paul D.12,Douglass Michael J. J.123

Affiliation:

1. School of Physics Chemistry and Earth Sciences The University of Adelaide Adelaide South Australia Australia

2. Department of Medical Physics Royal Adelaide Hospital Adelaide South Australia Australia

3. Australian Bragg Centre for Proton Therapy and Research South Australian Health and Medical Research Institute Adelaide South Australia Australia

Abstract

AbstractBackgroundThe use of Computed Tomography (CT) imaging data to create 3D printable patient‐specific devices for radiation oncology purposes is already well established in the literature and has shown to have superior conformity than conventional methods. Using non‐ionizing radiation imaging techniques such as photogrammetry or laser scanners in‐lieu of a CT scanner presents many desirable benefits including reduced imaging dose and fabrication of the device can be completed prior to simulation. With recent advancements in smartphone‐based technology, photographic and LiDAR‐based technologies are more readily available than ever before and to a high level of quality. As a result, these non‐ionizing radiation imaging methods are now able to generate patient‐specific devices that can be acceptable for clinical use.PurposeIn this work, we aim to determine if smartphones can be used by radiation oncologists or other radiation oncology staff to generate bolus or brachytherapy surface moulds instead of conventional CT with equivalent or comparable accuracy.MethodsThis work involved two separate studies: a phantom and participant study. For the phantom study, a RANDO anthropomorphic phantom (limited to the nose region) was used to generate 3D models based on three different imaging techniques: conventional CT, photogrammetry & LiDAR which were both acquired on a smartphone. Virtual boli were designed in Blender and 3D printed from PLA plastic material. The conformity of each printed boli was assessed by measuring the air gap volume and approximate thickness between the phantom & bolus acquired together on a CT. For the participant study, photographs, and a LiDAR scan of four volunteers were captured using an iPhone 13 Pro™ to assess their feasibility for generating human models. Each virtual 3D model was visually assessed to identify any issues in their reconstruction. The LiDAR models were registered to the photogrammetry models where a distance to agreement analysis was performed to assess their level of similarity. Additionally, a 3D virtual bolus was designed and printed using ABS material from all models to assess their conformity onto the participants skin surface using a verbal feedback method.ResultsThe photogrammetry derived bolus showed comparable conformity to the CT derived bolus while the LiDAR derived bolus showed poorer conformity as shown by their respective air gap volume and thickness measurements. The reconstruction quality of both the photogrammetry and LiDAR models of the volunteers was inadequate in regions of facial hair and occlusion, which may lead to clinically unacceptable patient‐specific device that are created from these areas. All participants found the photogrammetry 3D printed bolus to conform to their nose region with minimal room to move while three of the four participants found the LiDAR was acceptable and could be positioned comfortably over their entire nose.ConclusionsSmartphone‐based photogrammetry and LiDAR software show great potential for future use in generating 3D reference models for radiation oncology purposes. Further investigations into whether they can be used to fabricate clinically acceptable patient‐specific devices on a larger and more diverse cohort of participants and anatomical locations is required for a thorough validation of their clinical usefulness.

Publisher

Wiley

Reference27 articles.

1. Evaluation of optical 3D scanning system for radiotherapy use

2. Assessing the fit of 3D printed bolus from CT, optical scanner and photogrammetry methods;Maxwell S;Phys Eng Sci Med,2020

3. Application of optical photogrammetry in radiation oncology: HDR surface mold brachytherapy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3