Depth‐encoding using optical photon TOF in a prism‐PET detector with tapered crystals

Author:

Zeng Xinjie12,LaBella Andy3,Wang Zipai14,Li Yixin12,Tan Wanbin14,Goldan Amir H.1

Affiliation:

1. Department of Radiology, Weill Cornell Medical College Cornell University New York New York USA

2. Department of Electrical and Computer Engineering, College of Engineering and Applied Sciences Stony Brook University Stony Brook New York USA

3. Department of Radiology, Renaissance School of Medicine Stony Brook University Stony Brook New York USA

4. Department of Biomedical Engineering, College of Engineering and Applied Sciences Stony Brook University Stony Brook New York USA

Abstract

AbstractBackgroundHigh‐resolution brain positron emission tomography (PET) scanner is emerging as a significant and transformative non‐invasive neuroimaging tool to advance neuroscience research as well as improve diagnosis and treatment in neurology and psychiatry. Time‐of‐flight (TOF) and depth‐of‐interaction (DOI) information provide markedly higher PET imaging performance by increasing image signal‐to‐noise ratio and mitigating spatial resolution degradation due to parallax error, respectively. PET detector modules that utilize light sharing can inherently carry DOI information from the multiple timestamps that are generated per gamma event. The difference between two timestamps that are triggered by scintillation photons traveling in opposite directions signifies the event's depth‐dependent optical photon TOF (oTOF). However, light leak at the crystal‐readout interface substantially degrades the resolution of this oTOF‐based depth encoding.PurposeWe demonstrate the feasibility of oTOF‐based depth encoding by mitigating light leak in single‐ended‐readout Prism‐PET detector modules using tapered crystals. Minimizing light leak also improved both energy‐based DOI and coincidence timing resolutions.MethodsThe tapered Prism‐PET module consists of a 16  16 array of 1.5  1.5  20  lutetium yttrium oxyorthosillicate (LYSO) crystals, which are tapered down to 1.2  1.2  at the crystal‐readout interface. The LYSO array couples 4‐to‐1 to an 8  8 array of 3  3  silicon photomultiplier (SiPM) pixels on the tapered end and to a segmented prismatoid light guide array on the opposite end. Performance of tapered and non‐tapered Prism‐PET detectors was experimentally characterized and evaluated by measuring flood histogram, energy resolution, energy‐, and oTOF‐based DOI resolutions, and coincidence timing resolution. Sensitivities of scanners using different Prism‐PET detector designs were simulated using Geant4 application for tomographic emission (GATE).ResultsFor the tapered (non‐tapered) Prism‐PET module, the measured full width at half maximum (FWHM) energy, timing, energy‐based DOI, and oTOF‐based DOI resolutions were 8.88 (11.18)%, 243 (286) ps, 2.35 (3.18) mm, and 5.42 (13.87) mm, respectively. The scanner sensitivities using non‐tapered and tapered crystals, and 10 rings of detector modules, were simulated to be 30.9 and 29.5 kcps/MBq, respectively.ConclusionsThe tapered Prism‐PET module with minimized light leak enabled the first experimental report of oTOF‐based depth encoding at the detector module level. It also enabled the utilization of thinner (i.e., 0.1 mm) inter‐crystal spacing with barium sulfate as the reflector while also improving energy‐based DOI and timing resolutions.

Funder

National Institutes of Health

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3