Reducing thermal noise in high‐resolution quantitative magnetic resonance imaging rotating frame relaxation mapping of the human brain at 3 T

Author:

Ponticorvo Sara1ORCID,Canna Antonietta12,Moeller Steen1,Akcakaya Mehmet13,Metzger Gregory J.1,Filip Pavel14ORCID,Eberly Lynn E.15,Michaeli Shalom1,Mangia Silvia1ORCID

Affiliation:

1. Center for Magnetic Resonance Research University of Minnesota Minneapolis Minnesota USA

2. Montreal Neurological Institute and Hospital, the Neuro McGill University Montréal Quebec Canada

3. Electrical and Computer Engineering University of Minnesota Minneapolis Minnesota USA

4. Department of Neurology, First Faculty of Medicine and General University Hospital Charles University Prague Czech Republic

5. Division of Biostatistics, School of Public Health University of Minnesota Minneapolis Minnesota USA

Abstract

AbstractQuantitative maps of rotating frame relaxation (RFR) time constants are sensitive and useful magnetic resonance imaging tools with which to evaluate tissue integrity in vivo. However, to date, only moderate image resolutions of 1.6 x 1.6 x 3.6 mm3 have been used for whole‐brain coverage RFR mapping in humans at 3 T. For more precise morphometrical examinations, higher spatial resolutions are desirable. Towards achieving the long‐term goal of increasing the spatial resolution of RFR mapping without increasing scan times, we explore the use of the recently introduced Transform domain NOise Reduction with DIstribution Corrected principal component analysis (T‐NORDIC) algorithm for thermal noise reduction. RFR acquisitions at 3 T were obtained from eight healthy participants (seven males and one female) aged 52 ± 20 years, including adiabatic T1ρ, T2ρ, and nonadiabatic Relaxation Along a Fictitious Field (RAFF) in the rotating frame of rank n = 4 (RAFF4) with both 1.6 x 1.6 x 3.6 mm3 and 1.25 x 1.25 x 2 mm3 image resolutions. We compared RFR values and their confidence intervals (CIs) obtained from fitting the denoised versus nondenoised images, at both voxel and regional levels separately for each resolution and RFR metric. The comparison of metrics obtained from denoised versus nondenoised images was performed with a two‐sample paired t‐test and statistical significance was set at p less than 0.05 after Bonferroni correction for multiple comparisons. The use of T‐NORDIC on the RFR images prior to the fitting procedure decreases the uncertainty of parameter estimation (lower CIs) at both spatial resolutions. The effect was particularly prominent at high‐spatial resolution for RAFF4. Moreover, T‐NORDIC did not degrade map quality, and it had minimal impact on the RFR values. Denoising RFR images with T‐NORDIC improves parameter estimation while preserving the image quality and accuracy of all RFR maps, ultimately enabling high‐resolution RFR mapping in scan times that are suitable for clinical settings.

Funder

National Center for Advancing Translational Sciences

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3