Second sensor to improve near‐infrared spectroscopy flap monitor utility: A prospective study

Author:

Harper Jonathan1,Slade Emily2,Cornette Adrianne3,Kejner Alexandra E.4

Affiliation:

1. Department of Otolaryngology‐Head and Neck Surgery University of Kentucky Lexington Kentucky USA

2. Department of Biostatistics University of Kentucky Lexington Kentucky USA

3. Department of Pediatrics University Hospitals Cleveland, OH United States

4. Department of Otolaryngology ‐ Head and Neck Surgery Medical University of South Carolina Charleston South Carolina United States

Abstract

AbstractObjectiveThis study assesses whether use of continuous noninvasive near‐infrared spectroscopy (NIRS) sensor on head and neck free flap (FF) with a second sensor on nonoperated tissue improves distinction between systemic hypoperfusion and FF compromise.MethodsSingle‐institution, prospective study of patients undergoing head and neck FF reconstruction from December 2018 to April 2020. FFs were continuously monitored using NIRS on a monitor paddle with a second (control) sensor on the shoulder. Crude StO2 and percent change in StO2 were compared between the FF and control sensors on each patient, and percent change and percent difference between the control and the monitor paddle were documented to assess for congruity. Sentinel events (e.g., hypotension and hematoma) were documented to assess the association with change in StO2. These events and timing of StO2 changes were noted to assess associations with change in StO2.ResultsA total of 48 patients had complete data. Donor sites included 35 soft‐tissue FFs and 13 fibula FFs. Average StO2 was 73.7 ± 5.5 for FFs and 71.4 ± 5.0 for control sensors. There were seven sentinel events during the study. At the time of the events, StO2 dropped significantly more for the FF than the control sensor (FF = 52.2% drop; control = 6.2% drop; p = .016). NIRS signal denoted change prior to changes in implantable arterial Doppler in all cases.ConclusionsThe addition of a second sensor when using NIRS as a primary modality for FF monitoring may improve distinction between FF compromise events and systemic hypoperfusion. By increasing accuracy of the monitor, there is a potential for decreased resident burden and decreased use of higher level of care nursing, which could reduce overall costs.

Publisher

Wiley

Reference17 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3