Dosimetric study for breathing‐induced motion effects in an abdominal pancreas phantom for carbon ion mini‐beam radiotherapy

Author:

Stengl Christina123ORCID,Muñoz Iván D.234ORCID,Arbes Eric45ORCID,Rauth Evelyn45ORCID,Christensen Jeppe B.6ORCID,Vedelago José237ORCID,Runz Armin23,Jäkel Oliver238ORCID,Seco Joao45

Affiliation:

1. Medical Faculty Heidelberg Heidelberg University Heidelberg Germany

2. Division of Medical Physics in Radiation Oncology German Cancer Research Center (DKFZ) Heidelberg Germany

3. Heidelberg Institute for Radiation Oncology (HIRO) National Center for Radiation Research in Oncology (NCRO) Heidelberg Germany

4. Department for Physics and Astronomy Heidelberg University Heidelberg Germany

5. Biomedical Physics in Radiation Oncology German Cancer Research Center (DKFZ) Heidelberg Germany

6. Department of Radiation Safety and Security Paul Scherrer Institute (PSI) Villigen Switzerland

7. Department of Radiation Oncology Heidelberg University Hospital (UKHD) Heidelberg Germany

8. Heidelberg Ion Beam Therapy Center (HIT), Department of Radiation Oncology Heidelberg University Hospital (UKHD) Heidelberg Germany

Abstract

AbstractBackgroundParticle mini‐beam therapy exhibits promise in sparing healthy tissue through spatial fractionation, particularly notable for heavy ions, further enhancing the already favorable differential biological effectiveness at both target and entrance regions. However, breathing‐induced organ motion affects particle mini‐beam irradiation schemes since the organ displacements exceed the mini‐beam structure dimensions, decreasing the advantages of spatial fractionation.PurposeIn this study, the impact of breathing‐induced organ motion on the dose distribution was examined at the target and organs at risk(OARs) during carbon ion mini‐beam irradiation for pancreatic cancer.MethodsAs a first step, the carbon ion mini‐beam pattern was characterized with Monte Carlo simulations. To analyze the impact of breathing‐induced organ motion on the dose distribution of a virtual pancreas tumor as target and related OARs, the anthropomorphic Pancreas Phantom for Ion beam Therapy (PPIeT) was irradiated with carbon ions. A mini‐beam collimator was used to deliver a spatially fractionated dose distribution. During irradiation, varying breathing motion amplitudes were induced, ranging from 5 to 15 mm. Post‐irradiation, the 2D dose pattern was analyzed, focusing on the full width at half maximum (FWHM), center‐to‐center distance (ctc), and the peak‐to‐valley dose ratio (PVDR).ResultsThe mini‐beam pattern was visible within OARs, while in the virtual pancreas tumor a more homogeneous dose distribution was achieved. Applied motion affected the mini‐beam pattern within the kidney, one of the OARs, reducing the PVDR from 3.78  0.12 to 1.478  0.070 for the 15 mm motion amplitude. In the immobile OARs including the spine and the skin at the back, the PVDR did not change within 3.4% comparing reference and motion conditions.ConclusionsThis study provides an initial understanding of how breathing‐induced organ motion affects spatial fractionation during carbon ion irradiation, using an anthropomorphic phantom. A decrease in the PVDR was observed in the right kidney when breathing‐induced motion was applied, potentially increasing the risk of damage to OARs. Therefore, further studies are needed to explore the clinical viability of mini‐beam radiotherapy with carbon ions when irradiating abdominal regions.

Funder

Helmholtz Association

Deutscher Akademischer Austauschdienst

Publisher

Wiley

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3