In vivo diffusion MRI of the human heart using a 300 mT/m gradient system

Author:

Afzali Maryam12ORCID,Mueller Lars1ORCID,Coveney Sam1ORCID,Fasano Fabrizio34ORCID,Evans Christopher John2ORCID,Engel Maria2ORCID,Szczepankiewicz Filip5,Teh Irvin1ORCID,Dall'Armellina Erica1ORCID,Jones Derek K.2ORCID,Schneider Jürgen E.1ORCID

Affiliation:

1. Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine University of Leeds Leeds UK

2. Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology Cardiff University Cardiff UK

3. Siemens Healthcare Ltd Camberly UK

4. Siemens Healthcare GmbH Erlangen Germany

5. Medical Radiation Physics, Clinical Sciences Lund Lund University Lund Sweden

Abstract

AbstractPurposeThis work reports for the first time on the implementation and application of cardiac diffusion‐weighted MRI on a Connectom MR scanner with a maximum gradient strength of 300 mT/m. It evaluates the benefits of the increased gradient performance for the investigation of the myocardial microstructure.MethodsCardiac diffusion‐weighted imaging (DWI) experiments were performed on 10 healthy volunteers using a spin‐echo sequence with up to second‐ and third‐order motion compensation ( and ) and , and 1000 (twice the commonly used on clinical scanners). Mean diffusivity (MD), fractional anisotropy (FA), helix angle (HA), and secondary eigenvector angle (E2A) were calculated for b = [100, 450] and b = [100, 1000] for both and .ResultsThe MD values with are slightly higher than with with for and for . A reduction in MD is observed by increasing the from 450 to 1000 ( for and for ). The difference between FA, E2A, and HA was not significant in different schemes ().ConclusionThis work demonstrates cardiac DWI in vivo with higher b‐value and higher order of motion compensated diffusion gradient waveforms than is commonly used. Increasing the motion compensation order from to and the maximum b‐value from 450 to 1000 affected the MD values but FA and the angular metrics (HA and E2A) remained unchanged. Our work paves the way for cardiac DWI on the next‐generation MR scanners with high‐performance gradient systems.

Funder

Engineering and Physical Sciences Research Council

Wellcome Trust

British Heart Foundation

Publisher

Wiley

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献