Reproducibility of Quantitative Double‐Echo Steady‐State T2 Mapping of Knee Cartilage

Author:

Williams Ashley A.12ORCID,Asay Jessica L.3,Asare Daniella2,Desai Arjun D.34,Gold Garry E.35ORCID,Hargreaves Brian A.345,Chaudhari Akshay S.36ORCID,Chu Constance R.12

Affiliation:

1. Department of Orthopaedic Surgery Stanford University Stanford California USA

2. VA Palo Alto Health Care System Palo Alto California USA

3. Department of Radiology Stanford University Stanford California USA

4. Department of Electrical Engineering Stanford University Stanford California USA

5. Department of Bioengineering Stanford University Stanford California USA

6. Department of Biomedical Data Science Stanford University Stanford California USA

Abstract

BackgroundCartilage T2 can detect joints at risk of developing osteoarthritis. The quantitative double‐echo steady state (qDESS) sequence is attractive for knee cartilage T2 mapping because of its acquisition time of under 5 minutes. Understanding the reproducibility errors associated with qDESS T2 is essential to profiling the technical performance of this biomarker.PurposeTo examine the combined acquisition and segmentation reproducibility of knee cartilage qDESS T2 using two different regional analysis schemes: 1) manual segmentation of subregions loaded during common activities and 2) automatic subregional segmentation.Study TypeProspective.Subjects11 uninjured participants (age: 28 ± 3 years; 8 (73%) female).Field Strength/Sequence3‐T, qDESS.AssessmentTest–retest T2 maps were acquired twice on the same day and with a 1‐week interval between scans. For each acquisition, average cartilage T2 was calculated in four manually segmented regions encompassing tibiofemoral contact areas during common activities and 12 automatically segmented regions from the deep‐learning open‐source framework for musculoskeletal MRI analysis (DOSMA) encompassing medial and lateral anterior, central, and posterior tibiofemoral regions. Test–retest T2 values from matching regions were used to evaluate reproducibility.Statistical TestsCoefficients of variation (%CV), root‐mean‐square‐average‐CV (%RMSA‐CV), and intraclass correlation coefficients (ICCs) assessed test–retest T2 reproducibility. The median of test–retest standard deviations was used for T2 precision. Bland–Altman (BA) analyses examined test–retest biases. The smallest detectable difference (SDD) was defined as the BA limit of agreement of largest magnitude. Significance was accepted for P < 0.05.ResultsAll cartilage regions across both segmentation schemes demonstrated intraday and interday qDESS T2 CVs and RMSA‐CVs of ≤5%. T2 ICC values >0.75 were observed in the majority of regions but were more variable in interday tibial comparisons. Test–retest T2 precision was <1.3 msec. The T2 SDD was 3.8 msec.Data ConclusionExcellent CV and RMSA‐CV reproducibility may suggest that qDESS T2 increases or decreases >5% (3.8 msec) could represent changes to cartilage composition.Level of Evidence2.Technical EfficacyStage 2.

Funder

U.S. Department of Defense

National Institutes of Health

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3