Improving Microstructural Estimation in Time‐Dependent Diffusion MRI With a Bayesian Method

Author:

Liu Kuiyuan1ORCID,Lin Zixuan1ORCID,Zheng Tianshu1,Ba Ruicheng1,Zhang Zelin1,Li Haotian1,Zhang Hongxi2,Tal Assaf3,Wu Dan12ORCID

Affiliation:

1. Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science Zhejiang University Hangzhou China

2. Department of Radiology, Children's Hospital Zhejiang University School of Medicine Hangzhou China

3. Department of Chemical and Biological Physics Weizmann Institute of Science Rehovot Israel

Abstract

BackgroundAccurately fitting diffusion‐time‐dependent diffusion MRI (td‐dMRI) models poses challenges due to complex and nonlinear formulas, signal noise, and limited clinical data acquisition.PurposeIntroduce a Bayesian methodology to refine microstructural fitting within the IMPULSED (Imaging Microstructural Parameters Using Limited Spectrally Edited Diffusion) model and optimize the prior distribution within the Bayesian framework.Study TypeRetrospective.PopulationInvolving 69 pediatric patients (median age 6 years, interquartile range [IQR] 3–9 years, 61% male) with 41 low‐grade and 28 high‐grade gliomas, of which 76.8% were identified within the brainstem or cerebellum.Field Strength/Sequence3 T, oscillating gradient spin‐echo (OGSE) and pulsed gradient spin‐echo (PGSE).AssessmentThe Bayesian method's performance in fitting cell diameter (), intracellular volume fraction (), and extracellular diffusion coefficient () was compared against the NLLS method, considering simulated and experimental data. The tumor region‐of‐interest (ROI) were manually delineated on the b0 images. The diagnostic performance in distinguishing high‐ and low‐grade gliomas was assessed, and fitting accuracy was validated against H&E‐stained pathology.Statistical TestsT‐test, receiver operating curve (ROC), area under the curve (AUC) and DeLong's test were conducted. Significance considered at P < 0.05.ResultsBayesian methodology manifested increased accuracy with robust estimates in simulation (RMSE decreased by 29.6%, 40.9%, 13.6%, and STD decreased by 29.2%, 43.5%, and 24.0%, respectively for , , and compared to NLLS), indicating fewer outliers and reduced error. Diagnostic performance for tumor grade was similar in both methods, however, Bayesian method generated smoother microstructural maps (outliers ratio decreased by 45.3% ± 19.4%) and a marginal enhancement in correlation with H&E staining result (r = 0.721 for compared to r = 0.698 using NLLS, P = 0.5764).Data ConclusionThe proposed Bayesian method substantially enhances the accuracy and robustness of IMPULSED model estimation, suggesting its potential clinical utility in characterizing cellular microstructure.Evidence Level3Technical EfficacyStage 1

Funder

Ministry of Science and Technology of the People's Republic of China

Science and Technology Department of Zhejiang Province

National Natural Science Foundation of China

Publisher

Wiley

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3