Meta-analysis of superficial versus deep injection of radioactive tracer and blue dye for lymphatic mapping and detection of sentinel lymph nodes in breast cancer

Author:

Ahmed M1,Purushotham A D12,Horgan K3,Klaase J M4,Douek M12

Affiliation:

1. Research Oncology, Division of Cancer Studies, King's College London, London

2. Department of Breast Surgery, Guy's and St Thomas' NHS Foundation Trust, London

3. Department of Breast Surgery, University of Leeds, Leeds Teaching Hospitals NHS Trust, Leeds, UK

4. Department of Surgical Oncology, Medisch Spectrum Twente, Enschede, The Netherlands

Abstract

Abstract Background Sentinel lymph node biopsy (SLNB) is the standard of care for axillary staging in early breast cancer. Currently, no consensus exists on the optimal site of injection of the radioactive tracer or blue dye. Methods A systematic review and meta-analysis of studies comparing superficial and deep injections of radioactive tracer or blue dye for lymphatic mapping and SLNB was performed. The axillary and extra-axillary sentinel lymph node (SLN) identification rates obtained by lymphoscintigraphy and intraoperative SLNB were evaluated. Pooled odds ratios (ORs) and 95 per cent c.i. were estimated using fixed-effect analyses, or random-effects analyses if there was statistically significant heterogeneity (P < 0·050). Results Thirteen studies were included in the meta-analysis. There was no significant difference between superficial and deep injections of radioactive tracer for axillary SLN identification on lymphoscintigraphy (OR 1·59, 95 per cent c.i. 0·79 to 3·17), during surgery (OR 1·27, 0·60 to 2·68) and for SLN identification using blue dye (OR 1·40, 0·83 to 2·35). The rate of extra-axillary SLN identification was significantly greater when deep rather than superficial injection was used (OR 3·00, 1·92 to 4·67). The discordance rate between superficial and deep injections ranged from 4 to 73 per cent for axillary and from 0 to 61 per cent for internal mammary node mapping. Conclusion Both superficial and deep injections of radioactive tracer and blue dye are effective for axillary SLN identification. Clinical consequences of discordance rates between the two injection techniques are unclear. Deep injections are associated with significantly greater extra-axillary SLN identification; however, this may not have a significant impact on clinical management.

Publisher

Oxford University Press (OUP)

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3