Assessment of scintillation and Cherenkov imaging as beam shape verification method in CyberKnife® radiotherapy

Author:

Cui Fengwei12,Jin Tao12,Li Mingzhu3,Zhu Lei4,Di Xing12,Zhu Huaguang12

Affiliation:

1. CyberKnife Center Department of Neurosurgery Huashan Hospital Fudan University Shanghai China

2. Neurosurgical Institute of Fudan University Shanghai China

3. Department of Oncology The First Hospital of Hebei Medical University Hebei Medical University Shijiazhuang China

4. Department of Radiation Oncology Physics and Technology Shandong Cancer Hospital and Institute Shandong First Medical University and Shandong Academy of Medical Sciences Jinan City Shandong Province China

Abstract

AbstractPurposeThe goal of this study is to assess the utility of Cherenkov imaging (CI) and scintillation imaging (SI) as high‐resolution techniques to measure CyberKnife® beam shape quantitatively at the irradiation surface in quality assurance (QA).MethodsThe EMCCD camera captured scintillation and Cherenkov photons arising from 6 MV x‐ray dose deposition produced by the CyberKnife® VSI System. Two imaging methods were done at source to surface distance of 800 cm with the same field size, ranging from 10 to 60 mm using fixed cones and iris collimators. The output sensitivity and constancy were measured using the SI and CI, and benchmarked against an ionization chamber. Line profiles of each beam measured by optical imaging were compared with film measurement. Position shifts were introduced to test the sensitivity of SI and CI to small beam position deviations. To assess reproducibility, the beam measurements were tested three times on 5 consecutive days.ResultsBoth systems exhibited comparable sensitivity to the ionization chamber in response to fluctuations in CyberKnife® output. The beam profiles in SI matched well with the measured film image, with accuracy in the range of ± 0.20 and ± 0.26 mm standard deviation for the circle and iris field, respectively. The corresponding accuracy measured by CI is in the range of ± 0.25 and ± 0.33 mm, respectively. These are all within the tolerance recommended by the guidelines of CyberKnife® QA. The accuracy measured by SI and CI for 1 mm beam position shift within 0.21 and 0.45 mm tolerance, respectively. Repeatability measurements of the beam have shown a standard deviation within 0.94 mm.ConclusionsSI and CI techniques are tested to provide a valid way to measure CyberKnife® beam shape in this study. Meanwhile, the systematic comparison of SI and CI also provides evidence for the measurement methods selection appropriately.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3