Accuracy of abdominal organ motion estimation in radiotherapy using the right hemidiaphragm top as a surrogate during prolonged breath‐holds quantified with MRI

Author:

Veldman Johannes K.12,van Kesteren Zdenko12,Gunwhy Ebony R.12,Parkes Michael J.12,Stevens Markus F.3,van den Aardweg Joost G.4,van Tienhoven Geertjan12,Bel Arjan12,van Dijk Irma W.E.M.12

Affiliation:

1. Department of Radiation Oncology Amsterdam UMC location University of Amsterdam Amsterdam The Netherlands

2. Cancer Center Amsterdam Treatment and Quality of Life Amsterdam The Netherlands

3. Department of Anaesthesiology Amsterdam UMC location University of Amsterdam Amsterdam The Netherlands

4. Department of Pulmonology Amsterdam UMC location University of Amsterdam Amsterdam The Netherlands

Abstract

AbstractBackgroundRespiratory motion presents a challenge in radiotherapy of thoracic and upper abdominal tumors. Techniques to account for respiratory motion include tracking. Using magnetic resonance imaging (MRI) guided radiotherapy systems, tumors can be tracked continuously. Using conventional linear accelerators, tracking of lung tumors is possible by determining tumor motion on kilo voltage (kV) imaging. But tracking of abdominal tumors with kV imaging is hampered by limited contrast. Therefore, surrogates for the tumor are used. One of the possible surrogates is the diaphragm. However, there is no universal method for establishing the error when using a surrogate and there are particular challenges in establishing such errors during free breathing (FB). Prolonged breath‐holding might address these challenges.PurposeThe aim of this study was to quantify the error when using the right hemidiaphragm top (RHT) as surrogate for abdominal organ motion during prolonged breath‐holds (PBH) for possible application in radiation treatments.MethodsFifteen healthy volunteers were trained to perform PBHs in two subsequent MRI sessions (PBH‐MRI1 and PBH‐MRI2). From each MRI acquisition, we selected seven images (dynamics) to determine organ displacement during PBH by using deformable image registration (DIR). On the first dynamic, the RHT, right and left hemidiaphragm, liver, spleen and right and left kidney were segmented. We used the deformation vector fields (DVF), generated by DIR, to determine the displacement of each organ between two dynamics in inferior‐superior (IS), anterior‐posterior (AP), left‐right (LR) direction and we calculated the 3D vector magnitude (|d|). The displacements of the RHT, both hemidiaphragms and the abdominal organs were compared using a linear fit to determine the correlation (R2 of the fit) and the displacement ratio (DR, slope of the fit) between displacements of the RHT and each organ. We quantified the median difference between the DRs of PBH‐MRI1 and PBH‐MRI2 for each organ. Additionally, we estimated organ displacement in the second PBH by applying the DR from the first PBH to the displacement of the RHT measured during the second PBH. We compared the estimated organ displacement to the measured organ displacement during the second PBH. The difference between the two values was defined as the estimation error of using the RHT as a surrogate and assuming a constant DR over MRI sessions.ResultsThe linear relationships were confirmed by the high R2 values of the linear fit between the displacements of the RHT and the abdominal organs (R2 > 0.96) in the IS and AP direction and |d|, and high to moderate correlations in the LR direction (0.93 > R2 > 0.64). The median DR difference between PBH‐MRI1 and PBH‐MRI2 varied between 0.13 and 0.31 for all organs. The median estimation error of the RHT as a surrogate varied between 0.4 and 0.8 mm/min for all organs.ConclusionThe RHT could serve as an accurate surrogate for abdominal organ motion during radiation treatments, for example, in tracking, provided the error of the RHT as motion surrogate is taken into account in the margins.Trial registrationThe study was registered in the Netherlands Trial Register (NL7603).

Publisher

Wiley

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3