Evaluation of treatment planning system accuracy in estimating the stopping‐power ratio of immobilization devices for proton therapy

Author:

Jiang Kai1,MacFarlane Michael1,Mossahebi Sina1,Zakhary Mark J.1

Affiliation:

1. Department of Radiation Oncology University of Maryland School of Medicine Baltimore Maryland USA

Abstract

AbstractPurposeTo assess treatment planning system (TPS) accuracy in estimating the stopping‐power ratio (SPR) of immobilization devices commonly used in proton therapy and to evaluate the dosimetric effect of SPR estimation error for a set of clinical treatment plans.MethodsComputed tomography scans of selected clinical immobilization devices were acquired. Then, the water‐equivalent thickness (WET) and SPR values of these devices based on the scans were estimated in a commercial TPS. The reference SPR of each device was measured using a multilayer ion chamber (MLIC), and the differences between measured and TPS‐estimated SPRs were calculated. These findings were utilized to calculate corrected dose distributions of 15 clinical proton plans for three treatment sites: extremity, abdomen, and head‐and‐neck. The original and corrected dose distributions were compared using a set of target and organs‐at‐risk (OARs) dose–volume histogram (DVH) parameters.ResultsOn average, the TPS‐estimated SPR was 19.5% lower (range, −35.1% to 0.2%) than the MLIC‐measured SPR. Due to the relatively low density of most immobilization devices used, the WET error was typically <1 mm, but up to 2.2 mm in certain devices. Overriding the SPR of the immobilization devices to the measured values did not result in significant changes in the DVH metrics of targets and most OARs. However, some critical OARs showed noticeable changes of up to 6.7% in maximum dose.ConclusionsThe TPS tends to underestimate the SPR of selected proton immobilization devices by an average of about 20%, but this does not induce major WET errors because of the low density of the devices. The dosimetric effect of this SPR error was negligible for most treatment sites, although the maximum dose of a few OARs exhibited noticeable variations.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3