Iterative image reconstruction with polar coordinate discretized system matrix for optical CT radiochromic gel dosimetry

Author:

Collins Steve1,Ogilvy Andy1,Huang Dominic2,Hare Warren2,Hilts Michelle13,Jirasek Andrew1

Affiliation:

1. Department of Physics University of British Columbia—Okanagan Kelowna British Columbia Canada

2. Department of Mathematics University of British Columbia—Okanagan Kelowna British Columbia Canada

3. Medical Physics BC Cancer—Kelowna Kelowna British Columbia Canada

Abstract

AbstractBackgroundGel dosimeters are a potential tool for measuring the complex dose distributions that characterize modern radiotherapy. A prototype tabletop solid‐tank fan‐beam optical CT scanner for readout of gel dosimeters was recently developed. This scanner does not have a straight raypath from source to detector, thus images cannot be reconstructed using filtered backprojection (FBP) and iterative techniques are required. Iterative image reconstruction requires a system matrix that describes the geometry of the imaging system. Stored system matrices can become immensely large, making them impractical for storage on a typical desktop computer.PurposeHere we develop a method to reduce the storage size of optical CT system matrices through use of polar coordinate discretization while accounting for the refraction in optical CT systems.MethodsA ray tracing simulator was developed to track the path of light rays as they traverse the different mediums of the optical CT scanner. Cartesian coordinate discretized system matrices (CCDSMs) and polar coordinate discretized system matrices (PCDSMs) were generated by discretizing the reconstruction area of the optical CT scanner into a Cartesian pixel grid and a polar coordinate pixel grid, respectively. The length of each ray through each pixel was calculated and used to populate the system matrices. To ensure equal weighting during iterative reconstruction, the radial rings of PCDSMs were asymmetrically spaced such that the area of each polar pixel was constant. Two clinical phantoms and several synthetic phantoms were produced and used to evaluate the reconstruction techniques under known conditions. Reconstructed images were analyzed in terms of spatial resolution, signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), signal nonuniformity (SNU), and Gamma map pass percentage.ResultsA storage size reduction of 99.72% was found when comparing a PCDSM to a CCDSM with the same total number of pixels. Images reconstructed with a PCDSM were found to have superior SNR, CNR, SNU, and Gamma (1 mm, 1%) pass percentage compared to those reconstructed with a CCDSM. Increasing spatial resolution in the radial direction with increasing radial distance was found in both PCDSM and CCDSM reconstructions due to the outer regions refracting light more severely. Images reconstructed with a PCDSM showed a decrease in spatial resolution in the azimuthal directions as radial distance increases, due to the widening of the polar pixels. However, this can be mitigated with only a slight increase in storage size by increasing the number of projections. A loss of spatial resolution in the radial direction within 5 mm radially from center was found when reconstructing with a PCDSM, due to the large innermost pixels. However, this was remedied by increasing the number of radial rings within the PCDSM, yielding radial spatial resolution on par with images reconstructed with a CCDSM and a storage size reduction of 99.26%.ConclusionsDiscretizing the image pixel elements in polar coordinates achieved a system matrix storage size reduction of 99.26% with only minimal reduction in the image quality.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3