Assay of iodine monochloride via iodination of 2‐chloroaniline using reversed‐phase liquid chromatography

Author:

Purushottam Sutar12,Kumar Ajay13,Ganesh Chaturbhuj1ORCID

Affiliation:

1. Department of Pharmaceutical Sciences and Technology Institute of Chemical Technology Mumbai Maharashtra India

2. Customer Support Centre Shimadzu Analytical (India) Pvt. Ltd. Mumbai Maharashtra India

3. Registration Department R & D Center UPL Ltd. Thane India

Abstract

AbstractIodine monochloride is conventionally determined using the sodium thiosulphate titration method. Recently, mono‐iodination of 2‐chloroaniline in N,N‐dimethylformamide has been reported in the presence of iodine monochloride. A reversed‐phase high‐performance liquid chromatography method for the assay of iodine monochloride on the C18 column has been developed via the iodination of 2‐chloroaniline. Chromatographic separation was achieved using gradient elution with water and acetonitrile as mobile phase at 1 ml/min flow rate and detection at 304 nm. The elution of 2‐chloro‐4‐iodoaniline was observed at 5.492 min. Under the given experimental conditions, an excess of 2‐chloroaniline dissolved in acetonitrile reacted with a known amount of pure iodine monochloride resulting in 2‐chloro‐4‐iodoaniline. The amount of 2‐chloro‐4‐iodoaniline formed is a measure of the initial iodine monochloride concentration, thus providing the assay of iodine monochloride. The method was validated as per the guidelines of the International Conference on Harmonization guidelines and found to be linear (r2 = 0.999) and accurate (98%–102%) for iodine monochloride concentrations ranging from 0.4 to 1.2 mg/ml. The intra‐day and inter‐day precision were within 1%. The validated method was successfully applied to determine the assay of commercially available iodine monochloride, Wijs solution, and in‐situ generated iodine monochloride samples. Thus, a novel, simple, accurate, and precise HPLC method has been developed for iodination monochloride assay.

Publisher

Wiley

Subject

Filtration and Separation,Analytical Chemistry

Reference11 articles.

1. BrisboisRG WankeRA StubbsKA StickRV EllervikU I‐Cl.e‐EROS.Encyclopedia of reagents for organic synthesis.2013:1–6.

2. NCBSI/KI: A Reagent System for Iodination of Aromatics through In Situ Generation of I-Cl

3. Iodine monochloride as volumetric reagent

4. Oils and fats. AOAC official methods of analysis;Firestone D;USFDA,2000

5. https://corn.org/wp‐content/uploads/2009/12/H‐32.pdfAccessed October 26 2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3