Anisotropy, Anatomical Region, and Additional Variables Influence Young's Modulus of Bone: A Systematic Review and Meta‐Analysis

Author:

Kovács Krisztián12ORCID,Váncsa Szilárd234,Agócs Gergely25,Harnos Andrea26,Hegyi Péter234,Weninger Viktor12ORCID,Baross Katinka2,Kovács Bence2,Soós Gergely2,Kocsis György12

Affiliation:

1. Department of Orthopaedics Semmelweis University Budapest Hungary

2. Centre for Translational Medicine Semmelweis University Budapest Hungary

3. Institute for Translational Medicine, Szentágothai Research Centre, Medical School University of Pécs Pécs Hungary

4. Division of Pancreatic Diseases, Heart and Vascular Center Semmelweis University Budapest Hungary

5. Department of Biophysics and Radiation Biology Semmelweis University Budapest Hungary

6. Department of Biostatistics University of Veterinary Medicine Budapest Hungary

Abstract

ABSTRACTThe importance of finite element analysis (FEA) is growing in orthopedic research, especially in implant design. However, Young's modulus (E) values, one of the most fundamental parameters, can range across a wide scale. Therefore, our study aimed to identify factors influencing E values in human bone specimens. We report our systematic review and meta‐analysis based on the recommendation of the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses (PRISMA) 2020 guideline. We conducted the analysis on November 21, 2021. We included studies investigating healthy human bone specimens and reported on E values regarding demographic data, specimen characteristics, and measurement specifics. In addition, we included study types reporting individual specimen measurements. From the acquired data, we created a cohort in which we performed an exploratory data analysis that included the explanatory variables selected by random forest and regression trees methods, and the comparison of groups using independent samples Welch's t test. A total of 756 entries were included from 48 articles. Eleven different bones of the human body were included in these articles. The range of E values is between 0.008 and 33.7 GPa. The E values were most heavily influenced by the cortical or cancellous type of bone tested. Measuring method (compression, tension, bending, and nanoindentation), the anatomical region within a bone, the position of the bone within the skeleton, and the bone specimen size had a decreasing impact on the E values. Bone anisotropy, specimen condition, patient age, and sex were selected as important variables considering the value of E. On the basis of our results, E values of a bone change with bone characteristics, measurement techniques, and demographic variables. Therefore, the evaluation of FEA should be performed after the standardization of in vitro measurement protocol. © 2023 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

Publisher

Oxford University Press (OUP)

Subject

Orthopedics and Sports Medicine,Endocrinology, Diabetes and Metabolism

Reference93 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3