Feasibility of free‐breathing 19F MRI image acquisition to characterize ventilation defects in CF and healthy volunteers at wash‐in

Author:

Chung Sang Hun1ORCID,Huynh Khoi Minh1,Goralski Jennifer L.234,Chen Yong5,Yap Pew‐Thian6,Ceppe Agathe S.23,Powell Margret Z.3,Donaldson Scott H.23,Lee Yueh Z.26ORCID

Affiliation:

1. Department of Biomedical Engineering University of North Carolina at Chapel Hill Chapel Hill North Carolina USA

2. Division of Pulmonary and Critical Care Medicine University of North Carolina at Chapel Hill Chapel Hill North Carolina USA

3. Marsico Lung Institute/UNC Cystic Fibrosis Center University of North Carolina at Chapel Hill Chapel Hill North Carolina USA

4. Division of Pediatric Pulmonology University of North Carolina at Chapel Hill Chapel Hill North Carolina USA

5. Department of Radiology Case Western Reserve University Cleveland Ohio USA

6. Department of Radiology and Biomedical Research Imaging Center University of North Carolina at Chapel Hill Chapel Hill North Carolina USA

Abstract

PurposeTo explore the feasibility of measuring ventilation defect percentage (VDP) using 19F MRI during free‐breathing wash‐in of fluorinated gas mixture with postacquisition denoising and to compare these results with those obtained through traditional Cartesian breath‐hold acquisitions.MethodsEight adults with cystic fibrosis and 5 healthy volunteers completed a single MR session on a Siemens 3T Prisma. 1H Ultrashort‐TE MRI sequences were used for registration and masking, and ventilation images with 19F MRI were obtained while the subjects breathed a normoxic mixture of 79% perfluoropropane and 21% oxygen (O2). 19F MRI was performed during breath holds and while free breathing with one overlapping spiral scan at breath hold for VDP value comparison. The 19F spiral data were denoised using a low‐rank matrix recovery approach.ResultsVDP measured using 19F VIBE and 19F spiral images were highly correlated (r = 0.84) at 10 wash‐in breaths. Second‐breath VDPs were also highly correlated (r = 0.88). Denoising greatly increased SNR (pre‐denoising spiral SNR, 2.46 ± 0.21; post‐denoising spiral SNR, 33.91 ± 6.12; and breath‐hold SNR, 17.52 ± 2.08).ConclusionFree‐breathing 19F lung MRI VDP analysis was feasible and highly correlated with breath‐hold measurements. Free‐breathing methods are expected to increase patient comfort and extend ventilation MRI use to patients who are unable to perform breath holds, including younger subjects and those with more severe lung disease.

Funder

Cystic Fibrosis Foundation

Korea National Institute of Health

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3