The added value of diffusion tensor imaging with systematic bias correction for the assessment of liver morphology and physiology

Author:

Mazur‐Rosmus Weronika1,Spees William M.2,Krzyżak Artur T.1ORCID

Affiliation:

1. AGH University of Krakow Krakow Poland

2. Washington University in St. Louis St. Louis MO USA

Abstract

AbstractDiffusion‐weighted images of the human liver are prone to artifacts from bulk motions, poor SNR, non‐uniformity of magnetic field gradients, and non‐optimal choice of diffusion weightings. These factors markedly affect diffusion tensor imaging (DTI) metrics such as mean diffusivity (MD) and fractional anisotropy (FA).This work presents a simple preprocessing pipeline for enhanced magnetic field gradient non‐uniformity calibration and analysis of the systematic bias removal attained in each correction step.Liver DTI scans were conducted in two isotropic phantoms and one healthy volunteer. Diffusion tensor was calculated for the original data and after denoising, B1 correction, rigid body registration, and magnetic field gradient non‐uniformity correction applying the B‐matrix spatial distribution (BSD) method and then, compared with the standard approach (sDTI). MD and FA were determined in three segments of the right lobe from DTI using four different combinations of b‐values from the set 0, 400, and 800 s/mm2.Results showed that the proposed preprocessing and BSD methods have a significant impact on MD and FA values in off‐ and iso‐centered isotropic phantoms. The applied corrections applied to the human liver resulted in a 11% change in MD and a − 64% change in FA. By manipulating the b‐values used in the diffusion tensor calculation, DTI metrics that reflect only morphology or additional information about liver tissue physiology can be obtained.Accurate quantification of the human liver by diffusion requires appropriate preprocessing and carefully chosen b‐value.Noise, B1 inhomogeneity, mis‐registration, and non‐uniform magnetic field gradients significantly change distributions of DTI metrics in isotropic phantoms and the human liver. Basic preprocessing and the B‐matrix spatial distribution (BSD) method perform differently for off‐center and isocenter locations. In the human liver, they removed systematic bias of FA and MD by up to −63% and 11%, respectively. Visible variability of FA and MD among b‐value sets indicates the possibility of DTI sensitization to different liver compartments.

Funder

Agencja Badań Medycznych

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3