Comprehensive stereotactic radiosurgery platform characterization: A novel end‐to‐end approach with anthropomorphic 3D dosimetry

Author:

Wang Yi‐Fang1,Adamovics John2,Wuu Cheng‐Shie1

Affiliation:

1. Department of Radiation Oncology Columbia University Irving Medical Center New York New York USA

2. Department of Chemistry Rider University Lawrenceville New Jersey USA

Abstract

AbstractBackgroundStereotactic radiosurgery (SRS) is a widely employed strategy for intracranial metastases, utilizing linear accelerators and volumetric modulated arc therapy (VMAT). Ensuring precise linear accelerator performance is crucial, given the small planning target volume (PTV) margins. Rapid dose falloff is vital to minimize brain radiation necrosis. Despite advances in SRS planning, tools for end‐to‐end testing of SRS treatments are lacking, hindering confidence in the procedure.PurposeThis study introduces a novel end‐to‐end three‐dimensional (3D) anthropomorphic dosimetry system for characterization of a radiosurgery platform, aiming to measure planning metrics, dose gradient index (DGI), brain volumes receiving at least 10 and 12 Gy (V10, V12), as well as assess delivery uncertainties in multitarget treatments. The study also compares metrics from benchmark plans to enhance understanding and confidence in SRS treatments.MethodsThe developed anthropomorphic 3D dosimetry system includes a modified Stereotactic End‐to‐End Verification (STEEV) phantom with a customized insert integrating 3D dosimeters and a fiber optic CT scanner. Labview and MATLAB programs handle optical scanning, image preprocessing, and dosimetric analysis. SlicerRT is used for 3D dose visualization and analysis. A film stack insert was used to validate the 3D dosimeter measurements at specific slices. Benchmark plans were developed and measured to investigate off‐axis errors, dose spillage, small field dosimetry, and multi‐target delivery.ResultsThe accuracy of the developed 3D dosimetry system was rigorously assessed using radiochromic films. Two two‐dimensional (2D) dose planes, extracted from the 3D dose distribution, were compared with film measurements, resulting in high passing rates of 99.9% and 99.6% in gamma tests. The mean relative dose difference between film and 3D dosimeter measurements was −1%, with a standard deviation of 2.2%, well within dosimeter uncertainties. In the first module, evaluating single‐isocenter multitarget treatments, a 1.5 mm dose distribution shift was observed when targets were 7 cm off‐axis. This shift was attributed to machine mechanical errors and image‐guided system uncertainties, indicating potential limitations in conventional gamma tests. The second module investigated discrepancies in intermediate‐to‐low dose spillage, revealing higher measured doses in the connecting region between closely positioned targets. This discrepancy was linked to uncertainties in treatment planning system (TPS) modeling of out‐of‐field dose and multileaf collimator (MLC) characteristics, resulting in lower DGI values and higher V10 and V12 values compared to TPS calculations. In the third module, irradiating multiple targets showed consistent V10 and V12 values within 1 cm3 agreement with dose calculations. However, lower DGI values from measurements compared to calculations suggested intricacies in the treatment process. Conducting vital end‐to‐end testing demonstrated the anthropomorphic 3D dosimetry system's capacity to assess overall treatment uncertainty, offering a valuable tool for enhancing treatment accuracy in radiosurgery platforms.ConclusionsThe study introduces a novel anthropomorphic 3D dosimetry system for end‐to‐end testing of a radiosurgery platform. The system effectively measures plan quality metrics, captures mechanical errors, and visualizes dose discrepancies in 3D space. The comprehensive evaluation capability enhances confidence in the commissioning and verification process, ensuring patient safety. The system is recommended for commissioning new radiosurgery platforms and remote auditing of existing programs.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3