Liver Fat Quantification With Ultrasound: Depth Dependence of Attenuation Coefficient

Author:

Ferraioli Giovanna1ORCID,Raimondi Ambra12,Maiocchi Laura2,De Silvestri Annalisa3,Poma Gianluigi2,Kumar Viksit4,Barr Richard G5

Affiliation:

1. Department of Clinical, Surgical, Diagnostic and Pediatric Sciences University of Pavia Pavia Italy

2. Ultrasound Unit Fondazione IRCCS Policlinico S. Matteo Pavia Italy

3. Clinical Epidemiology and Biometric Unit Fondazione IRCCS Policlinico S. Matteo Pavia Italy

4. Center for Ultrasound Research & Translation, Department of Radiology Massachusetts General Hospital Boston Massachusetts USA

5. Department of Radiology Northeastern Ohio Medical University, Rootstown, Ohio; Southwoods Imaging Youngstown Ohio USA

Abstract

ObjectivesThe primary aim was to estimate the influence of various depths on ultrasound attenuation coefficient (AC) of multiple vendors in the liver. The secondary aim was to evaluate the impact of region of interest (ROI) size on AC measurements in a subset of participants.MethodsThis Institutional Review Board (IRB)‐approved Health Insurance Portability and Accountability Act (HIPAA)‐compliant retrospective study was carried out in two centers using AC‐Canon and AC‐Philips algorithms and extracting AC‐Siemens values from ultrasound‐derived fat fraction algorithm. Measurements were performed positioning ROI upper edge (3 cm size) at 2, 3, 4, 5 cm from the liver capsule with AC‐Canon and AC‐Philips and at 1.5, 2, 3 cm with Siemens algorithm. In a subset of participants, measurements were obtained with 1 and 3 cm ROI size. Univariate and multivariate linear regression models and Lin's concordance correlation coefficient (CCC) were used for statistical analysis as appropriate.ResultsThree different cohorts were studied. Sixty‐three participants (34 females; mean age: 51 ± 14 years) were studied with AC‐Canon, 60 (46 females; mean age: 57 ± 11 years) with AC‐Philips, and 50 (25 females; 61 ± 13 years) with AC‐Siemens. There was a decrease in AC values per 1 cm increase in depth in all. In multivariable analysis, the coefficient was −0.049 (−0.060; −0.038 P < .001) with AC‐Canon, −0.058 (−0.066; −0.049 P < .001) with AC‐Philips and −0.081 (−0.112; −0.050 P < .001) with AC‐Siemens. AC values with 1 cm ROI were significantly higher than those obtained with 3 cm ROI at all depths (P < .001) but the agreement between AC values obtained with different ROI size was excellent (CCC 0.82 [0.77–0.88]).ConclusionsThere is depth dependence in AC measurement that affects results. A standardized protocol with fixed ROI's depth and size is needed.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3