Candidate reference measurement procedure for serum 17‐hydroxyprogesterone quantification via isotope dilution liquid chromatography–tandem mass spectrometry

Author:

Zhang Ji1,Jiang Yang2ORCID,Liu Ting2,Liu Xiongwei3,Huang Hui2,Cheng Yanxiang2,Li Jieyan2,Cheng Bangning12,Qian Chungen2,Xiang Xufu24,Xu Jun‐Fa1

Affiliation:

1. Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics Department of Clinical Immunology Institute of Laboratory Medicine School of Medical Technology Guangdong Medical University Dongguan Guangdong China

2. Shenzhen YHLO Biotech Co., Ltd. Shenzhen Guangdong China

3. Shenzhen Longgang Central Hospital Clinical Laboratory Shenzhen Guangdong China

4. The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics‐Hubei Bioinformatics and Molecular Imaging Key Laboratory Systems Biology Theme Department of Biomedical Engineering College of Life Science and Technology Huazhong University of Science and Technology Wuhan Hubei China

Abstract

AbstractBackgroundAccurate quantification of 17‐hydroxyprogesterone (17‐OHP) in serum is vital for clinical and research applications. However, inter‐laboratory variability in test results exists owing to the lack of a standardized reference measurement procedure (RMP). Therefore, in this study, we developed a highly accurate, cost‐effective, and user‐friendly candidate RMP (cRMP) for analyzing 17‐OHP in serum.MethodsWe quantified 17‐OHP in serum using a one‐step liquid–liquid extraction method with the addition of 17‐OHP‐13C3, followed by liquid chromatography–tandem mass spectrometry. The ability of these methods to suppress interference was evaluated by chromatographic analysis. We assessed accuracy, specificity, the lower limit of quantitation, linearity, and matrix effects by following the standards specified by the Clinical and Laboratory Standards Institute. The consistency between the developed cRMP and the chemiluminescence method was evaluated through experiments with 120 clinical samples.ResultsThe developed cRMP required only 8 min for accurate quantification of serum 17‐OHP without bias from matrix effects or interference from 19 metabolites added as potential interferents. The method exhibited favorable measurement performance, with a quantitation limit of 0.086 ng/mL, linear range of 0.1–400 ng/mL, a total imprecision of ≤2.90%, spike recovery of 100.1%–100.6%, and relative deviations from assigned target values (RfB Institution) of −2.91% to 1.10%. The cRMP demonstrated good consistency with the conventional assay (chemiluminescence method), with a correlation coefficient R of 0.96977.ConclusionA cRMP with high accuracy, cost‐effectiveness, and convenient operation was developed for quantifying 17‐OHP in serum. Its simplicity and robust performance make it an invaluable addition to the arsenal of analytical tools available for laboratories. This method can enhance the accuracy and reliability of 17‐OHP measurements across various laboratories.

Funder

National Natural Science Foundation of China

Huazhong University of Science and Technology

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3