Zero to minimal fluoroscopy for cardiac electronic device implantation: A systematic review and meta‐analysis

Author:

Luke Kevin1ORCID,Milla Clonia1ORCID,Tandi Joshua Kurnia2,Julario Rerdin3

Affiliation:

1. Faculty of Medicine Universitas Airlangga Surabaya Indonesia

2. Faculty of Medicine Universitas Tarumanagara Jakarta Indonesia

3. Department of Cardiology and Vascular Medicine Dr. Soetomo General Hospital‐Universitas Airlangga Surabaya Indonesia

Abstract

AbstractBackgroundFluoroscopy is conventionally performed for cardiac implantable electronic device (CIED) therapy and carries radiation drawback for both patients and medical workers. Recently, zero to minimal fluoroscopy (ZMF) approach is introduced to reduce radiation exposure of fluoroscopy. This study compares the feasibility and safety of ZMF approach to fluoroscopy for CIEDs therapy in adults.MethodA systematic literature search was conducted on PubMed, ScienceDirect, and Web of Science in March 2023. All observational or experimental studies comparing ZMF approach to fluoroscopy for adult CIEDs therapy were included. Reviews, case report/series, animal studies, and non‐English articles were excluded. The success rate, procedural time, fluoroscopy time, radiation dose, and complications rate were compared for each approach.ResultsSeven articles for permanent and three articles for temporary CIEDs were included for analysis. The success rate of ZMF for permanent CIEDs was similar to fluoroscopy method (OR: 0.77, 95% CI: 0.33–4.15). The procedural time of ZMF was similar to fluoroscopy for both permanent and temporary CIEDs (standardized mean difference [SMD]: 0.10, 95% CI: −0.35 to 0.55 and SMD: −0.71, 95% CI: −1.87–0.44, respectively). However, ZMF approach markedly reduced the fluoroscopy time and radiation exposure for permanent CIEDs (SMD: −1.80, 95% CI: −2.49 to −1.12 and SMD: −1.26, 95% CI: −2.24 to −0.29). The complication rate was similar for permanent CIEDs (OR: 1.08, 95% CI: 0.41–2.84), yet lowered for temporary CIEDs (OR: 0.34, 95% CI: 0.20–0.59).ConclusionZMF had similar success rate, procedural time, and sum complication rate for permanent CIEDs implantation with a significant reduction of fluoroscopy time and radiation exposure.

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine

Reference45 articles.

1. The impact of cardiac devices on patients' quality of life—a systematic review and meta‐analysis;Willy K;J Cardiovasc Dev Dis,2022

2. Cardiac implantable electronic device therapy in heart failure;Hussein AA;Circ Res,2019

3. Effect of fluoroscopy frame rate on radiation exposure and in‐hospital outcomes in cardiovascular implantable electronic device implantation procedures;Ali M;Radiat Med Prot,2021

4. Risks related to fluoroscopy radiation associated with electrophysiology procedures;Picano E;J Atr Fibrillation,2014

5. The use of minimal fluoroscopy for cardiac electrophysiology procedures: a meta‐analysis and review of the literature;Chiang LLW;Clin Cardiol,2021

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3