Cerclage augmentation of S1–S2 transsacral screw fixation in osteoporotic posterior pelvis ring injuries: A biomechanical feasibility study

Author:

Berk Till123ORCID,Zderic Ivan1ORCID,Schwarzenberg Peter1ORCID,Halvachizadeh Sascha23,Teuben Michel23ORCID,Richards Geoff1,Gueorguiev Boyko1ORCID,Pape Hans‐Christoph23

Affiliation:

1. Biomedical Development AO Research Institute Davos Davos Switzerland

2. Department of Trauma University Hospital Zurich Zurich Switzerland

3. Harald‐Tscherne Laboratory for Orthopedic and Trauma Research University of Zurich Zurich Switzerland

Abstract

AbstractInjuries of the posterior pelvic ring are predominantly associated with osteoporosis. Percutaneously placed screws transfixing the sacroiliac joint have become the gold standard for their treatment. However, screw cut‐out, backing‐out, and loosening are common complications. One promising option could be cerclage reinforcement of cannulated screw fixations. Therefore, the aim of this study was to evaluate the biomechanical feasibility of posterior pelvic ring injuries fixed with S1 and S2 transsacral screws augmented with cerclage. Twenty‐four composite osteoporotic pelvises with posterior sacroiliac joint dislocation were stratified into four groups for S1–S2 transsacral fixation using either (1) fully threaded screws, (2) fully threaded screws with cable cerclage, (3) fully threaded screws with wire cerclage, or (4) partially threaded screws with wire cerclage. All specimens were biomechanically tested under progressively increasing cyclic loading until failure. Intersegmental movements were monitored by motion tracking. The transsacral partially threaded screw fixation with wire cerclage augmentation resulted in significantly less combined angular intersegmental movement in the transverse and coronal plane versus its fully threaded counterpart (p = 0.032), as well as in significantly less flexion versus all other fixations (p ≤ 0.029). Additional cerclage augmentation could be performed intraoperatively to improve the stability of posterior pelvic ring injuries treated with S1–S2 transsacral screw fixation. Further investigations should follow to consolidate the current results on real bones and possibly consider execution of a clinical study.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3